Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Isolation
VI-24T-CW-F2 Vicor Corporation VI-24T-CW-F2 -
RFQ
ECAD 7718 0.00000000 Vicor Corporation VI-200™ (100W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-24T 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 15.38A 55V 90% 6.5V - - 3 kV
VI-24T-IY-F1 Vicor Corporation VI-24T-IY-F1 -
RFQ
ECAD 8859 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-24T 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 7.69A 55V 90% 6.5V - - 3 kV
VI-BTR-MY-B1 Vicor Corporation VI-BTR-MY-B1 -
RFQ
ECAD 8176 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BTR 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 6.67A 66V 90% 7.5V - - 3 kV
VI-J41-MX Vicor Corporation VI-J41-MX -
RFQ
ECAD 9348 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Obsolete -55°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J41 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 6.25A 55V 90% 12V - - 3 kV
VI-J43-CX-F4 Vicor Corporation VI-J43-CX-F4 -
RFQ
ECAD 2574 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J43 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 55V 90% 24V - - 3 kV
VI-J43-CZ-F2 Vicor Corporation VI-J43-CZ-F2 -
RFQ
ECAD 5759 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J43 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 25 W 1 1.04A 55V 90% 24V - - 3 kV
VI-J43-EX-B1 Vicor Corporation VI-J43-EX-B1 -
RFQ
ECAD 4837 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -10°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J43 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 55V 88% 24V - - 3 kV
VI-J43-IX Vicor Corporation VI-J43-IX 533.9700
RFQ
ECAD 8985 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J43 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 55V 90% 24V - - 3 kV
VI-24M-IW-F1 Vicor Corporation VI-24M-IW-F1 -
RFQ
ECAD 2145 0.00000000 Vicor Corporation VI-200™ (100W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-24M 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 10A 55V 90% 10V - - 3 kV
VI-24P-MX-F1 Vicor Corporation VI-24P-MX-F1 -
RFQ
ECAD 9105 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-24P 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 5.43A 55V 90% 13.8V - - 3 kV
VI-B43-EW-B1 Vicor Corporation VI-B43-EW-B1 -
RFQ
ECAD 7115 0.00000000 Vicor Corporation VI-200™ (100W) Bulk Active -10°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B43 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 4.17A 55V 88% 24V - - 3 kV
VI-B43-EX-S Vicor Corporation VI-B43-EX-S -
RFQ
ECAD 8618 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -10°C ~ 85°C ITE (Commercial) 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B43 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 3.13A 55V 88% 24V - - 3 kV
VI-B4M-IY-F3 Vicor Corporation VI-B4M-IY-F3 -
RFQ
ECAD 1808 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B4M 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 5A 55V 90% 10V - - 3 kV
VI-B4M-MX-F1 Vicor Corporation VI-B4M-MX-F1 -
RFQ
ECAD 1206 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 0.79" H (116.8mm x 47.2mm x 20.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B4M 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 7.5A 55V 90% 10V - - 3 kV
VI-B4N-CV-F4 Vicor Corporation VI-B4N-CV-F4 -
RFQ
ECAD 8463 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B4N 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 8.11A 55V 90% 18.5V - - 3 kV
VI-B4J-EY-S Vicor Corporation VI-B4J-EY-S -
RFQ
ECAD 6225 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -10°C ~ 85°C ITE (Commercial) 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B4J 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 1.39A 55V 88% 36V - - 3 kV
VI-B4L-CX-F2 Vicor Corporation VI-B4L-CX-F2 -
RFQ
ECAD 8264 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-B4L 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 2.68A 55V 90% 28V - - 3 kV
VI-BT1-CW-F2 Vicor Corporation VI-BT1-CW-F2 -
RFQ
ECAD 5440 0.00000000 Vicor Corporation VI-200™ (100W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BT1 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 100 W 1 4.17A 66V 90% 12V - - 3 kV
VI-BT1-MV-F4 Vicor Corporation VI-BT1-MV-F4 -
RFQ
ECAD 3957 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -55°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BT1 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 4.17A 66V 90% 12V - - 3 kV
VI-JTY-MZ-B1 Vicor Corporation VI-JTY-MZ-B1 -
RFQ
ECAD 1945 0.00000000 Vicor Corporation VI-J00™ (25W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.36" L x 2.28" W x 1.08" H (59.9mm x 57.9mm x 27.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JTY 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 17 W 1 5A 66V 90% 3.3V - - 3 kV
VI-JTZ-MX-S Vicor Corporation VI-JTZ-MX-S -
RFQ
ECAD 9228 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -55°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JTZ 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 30 W 1 15A 66V 90% 2V - - 3 kV
VI-BTX-CY-S Vicor Corporation VI-BTX-CY-S -
RFQ
ECAD 5015 0.00000000 Vicor Corporation VI-200™ (50W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BTX 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 9.62A 66V 90% 5.2V - - 3 kV
VI-BTX-IX-B1 Vicor Corporation VI-BTX-IX-B1 -
RFQ
ECAD 8311 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BTX 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 9.62A 66V 90% 5.2V - - 3 kV
VI-BTX-IX-F4 Vicor Corporation VI-BTX-IX-F4 -
RFQ
ECAD 1325 0.00000000 Vicor Corporation VI-200™ (75W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.86" W x 1.05" H (116.8mm x 47.2mm x 26.7mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BTX 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 9.62A 66V 90% 5.2V - - 3 kV
VI-BTY-IW-S Vicor Corporation VI-BTY-IW-S -
RFQ
ECAD 3029 0.00000000 Vicor Corporation VI-200™ (100W) Bulk Active -40°C ~ 85°C ITE (Commercial) 4.60" L x 1.80" W x 0.52" H (116.8mm x 45.7mm x 13.2mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BTY 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 66 W 1 20A 66V 90% 3.3V - - 3 kV
VI-BTZ-CV-B1 Vicor Corporation VI-BTZ-CV-B1 -
RFQ
ECAD 1548 0.00000000 Vicor Corporation VI-200™ (150W) Bulk Active -25°C ~ 85°C ITE (Commercial) 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) Through Hole Full Brick Isolated Module OCP, OTP, OVP, SCP VI-BTZ 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 60 W 1 30A 66V 90% 2V - - 3 kV
VI-J01-IY-S Vicor Corporation VI-J01-IY-S -
RFQ
ECAD 4863 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Obsolete -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.80" W x 0.52" H (57.9mm x 45.7mm x 13.2mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J01 20V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 4.17A 10V 90% 12V - - 3 kV
VI-J4H-IX Vicor Corporation VI-J4H-IX -
RFQ
ECAD 4522 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 2.40" W x 0.50" H (57.9mm x 70.0mm x 12.7mm) Through Hole Half Brick Isolated Module OCP, SCP VI-J4H 100V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 1.44A 55V 90% 52V - - 3 kV
VI-JT0-CY-F2 Vicor Corporation VI-JT0-CY-F2 429.6800
RFQ
ECAD 3777 0.00000000 Vicor Corporation VI-J00™ (50W) Bulk Active -25°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JT0 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 50 W 1 10A 66V 90% 5V - - 3 kV
VI-JTT-IX-F4 Vicor Corporation VI-JTT-IX-F4 -
RFQ
ECAD 7530 0.00000000 Vicor Corporation VI-J00™ (75W) Bulk Active -40°C ~ 100°C ITE (Commercial) 2.28" L x 1.86" W x 1.04" H (57.9mm x 47.2mm x 26.4mm) Through Hole Half Brick Isolated Module OCP, SCP VI-JTT 160V download RoHS non-compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 11.54A 66V 90% 6.5V - - 3 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2