Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Type | Features | Base Product Number | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Control Features | Current - Output (Max) | Voltage - Input (Min) | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Isolation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
REM3-2405S/A | 66.0200 | 9809 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-2405 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000018 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 600mA | 18V | 84.5% | 5V | - | - | 5 kV | ||||
REM3-2405S/A/CTRL | 69.3200 | 4268 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-2405 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000019 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 600mA | 18V | 84.5% | 5V | - | - | 5 kV | |||
REM3-0512S/A | 66.0200 | 4624 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | OCP, OVP, SCP, UVLO | REM3-0512 | 9V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000024 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 250mA | 4.5V | 85.5% | 12V | - | - | 5 kV | ||||
REM3-0512S/C | 66.0200 | 9664 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | OCP, OVP, SCP, UVLO | REM3-0512 | 9V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000026 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 250mA | 4.5V | 85.5% | 12V | - | - | 5 kV | ||||
REM3-1212S/A | 66.0200 | 7400 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-1212 | 18V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000027 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 250mA | 9V | 87% | 12V | - | - | 5 kV | ||||
REM3-2412S/A/CTRL | 69.3200 | 4508 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-2412 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000031 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 250mA | 18V | 87% | 12V | - | - | 5 kV | |||
REM3-4812S/C | 66.0200 | 8130 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4812 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000035 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 250mA | 36V | 87% | 12V | - | - | 5 kV | ||||
REM3-4815S/A/CTRL | 69.3200 | 2966 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4815 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000046 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 200mA | 36V | 86.5% | 15V | - | - | 5 kV | |||
REM3-2424S/A/CTRL | 69.3200 | 7789 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-2424 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000055 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 125mA | 18V | 87% | 24V | - | - | 5 kV | |||
REM3-0505D/A | 72.6100 | 4576 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | OCP, OVP, SCP, UVLO | REM3-0505 | 9V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000060 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | 300mA, 300mA | 4.5V | 83% | 5V | -5V | - | 5 kV | ||||
REM3-1205D/A | 72.6100 | 1624 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-1205 | 18V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000063 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | 300mA, 300mA | 9V | 83.5% | 5V | -5V | - | 5 kV | ||||
REM3-1205D/A/CTRL | 76.2600 | 4550 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 7 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-1205 | 18V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000064 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | Enable, Active Low | 300mA, 300mA | 9V | 83.5% | 5V | -5V | - | 5 kV | |||
REM3-4805SW/A | 69.3200 | 7015 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4805 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000105 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 600mA | 18V | 84% | 5V | - | - | 5 kV | ||||
REM3-4805SW/A/CTRL | 69.3200 | 3029 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4805 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000106 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 600mA | 18V | 84% | 5V | - | - | 5 kV | |||
REM3-4812SW/A/CTRL | 69.3200 | 4274 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4812 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000112 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 250mA | 18V | 87% | 12V | - | - | 5 kV | |||
REM3-4815SW/A | 69.3200 | 8611 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4815 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000117 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | 200mA | 18V | 86.5% | 15V | - | - | 5 kV | ||||
REM3-4815SW/A/CTRL | 69.3200 | 5163 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4815 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000118 | EAR99 | 8504.40.9580 | 7 | 3 W | 1 | Enable, Active Low | 200mA | 18V | 86.5% | 15V | - | - | 5 kV | |||
REM3-4812DW/A | 76.2600 | 6996 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4812 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000135 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | 125mA, 125mA | 18V | 86% | 12V | -12V | - | 5 kV | ||||
REM3-4812DW/A/CTRL | 80.0700 | 8397 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 7 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4812 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000136 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | Enable, Active Low | 125mA, 125mA | 18V | 86% | 12V | -12V | - | 5 kV | |||
REM3-2415DW/A | 76.2600 | 8172 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-2415 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000138 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | 100mA, 100mA | 9V | 86% | 15V | -15V | - | 5 kV | ||||
REM3-4815DW/A/CTRL | 80.0700 | 3525 | 0.00000000 | Recom Power | MEDLINE REM3 (3W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 7 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM3-4815 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000142 | EAR99 | 8504.40.9580 | 7 | 3 W | 2 | Enable, Active Low | 100mA, 100mA | 18V | 86% | 15V | -15V | - | 5 kV | |||
REM6-053.3S/A | 73.7000 | 4099 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-053.3 | 9V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000144 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | 1.8A | 4.5V | 81.5% | 3.3V | - | - | 5 kV | ||||
REM6-123.3S/C | 73.7000 | 5886 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-123.3 | 18V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000149 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | 1.8A | 9V | 83.5% | 3.3V | - | - | 5 kV | ||||
REM6-243.3S/A | 73.7000 | 7529 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-243.3 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000150 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | 1.8A | 18V | 83% | 3.3V | - | - | 5 kV | ||||
REM6-483.3S/A/CTRL | 78.1200 | 5762 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-483.3 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000154 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | Enable, Active Low | 1.8A | 36V | 82.5% | 3.3V | - | - | 5 kV | |||
REM6-1205S/A/CTRL | 77.3800 | 3269 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-1205 | 18V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000160 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | Enable, Active Low | 1.2A | 9V | 86% | 5V | - | - | 5 kV | |||
REM6-2405S/A | 73.7000 | 1030 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-2405 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000162 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | 1.2A | 18V | 86% | 5V | - | - | 5 kV | ||||
REM6-2405S/C | 74.4000 | 7 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-2405 | 36V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000164 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | 1.2A | 18V | 86% | 5V | - | - | 5 kV | ||||
REM6-4805S/A | 73.7000 | 5325 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 5 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-4805 | 75V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000165 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | 1.2A | 36V | 86.5% | 5V | - | - | 5 kV | ||||
REM6-1212S/A/CTRL | 77.3800 | 3733 | 0.00000000 | Recom Power | MEDLINE REM6 (6W) | Tube | Active | -40°C ~ 105°C | ITE (Commercial), Medical | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | Through Hole | 24-DIP Module, 6 Leads | Isolated Module | Remote On/Off, OCP, OVP, SCP, UVLO | REM6-1212 | 18V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 51000172 | EAR99 | 8504.40.9580 | 7 | 6 W | 1 | Enable, Active Low | 500mA | 9V | 89% | 12V | - | - | 5 kV |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse