SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
TMR 1-1212 Traco Power TMR 1-1212 10.1400
RFQ
ECAD 23 0.00000000 Traco Power TMR 1 (1W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.67" L x 0.30" W x 0.43" H (17.0mm x 7.6mm x 11.0mm) Through Hole 6-SIP Module, 4 Leads Isolated Module OCP, SCP TMR 1 CB, CSA 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2336 EAR99 8504.40.9580 10 996 mW 1 - 83mA 9V 77% 12V - - - 1.5 kV
TMR 1223 Traco Power TMR 1223 16.9100
RFQ
ECAD 30 0.00000000 Traco Power TMR 2 (2W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 12 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2341 EAR99 8504.40.9580 10 2 W 2 65mA, 65mA 9V 84% 15V -15V - - 1.5 kV
TMR 1-2422 Traco Power TMR 1-2422 11.2500
RFQ
ECAD 3 0.00000000 Traco Power TMR 1 (1W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.67" L x 0.30" W x 0.43" H (17.0mm x 7.6mm x 11.0mm) Through Hole 6-SIP Module, 5 Leads Isolated Module OCP, SCP TMR 1 CB, CSA 36V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2344 EAR99 8504.40.9580 10 1 W 2 - 42mA, 42mA 18V 80% 12V -12V - - 1.5 kV
TMR 2-0511E Traco Power TMR 2-0511E 12.8400
RFQ
ECAD 60 0.00000000 Traco Power TMR 2E (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 2 9V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2346 EAR99 8504.40.9580 10 2 W 1 400mA 4.5V 73% 5V - - - 1 kV
TMR 2-2412WIN Traco Power TMR 2-2412WIN 15.5800
RFQ
ECAD 15 0.00000000 Traco Power TMR 2WIN (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.44" W x 0.37" H (21.8mm x 11.2mm x 9.3mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, OCP, SCP TMR 2 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2351 EAR99 8504.40.9580 10 2 W 1 167mA 9V 82% 12V - - - 1.5 kV
TMR 2-4811E Traco Power TMR 2-4811E 12.7200
RFQ
ECAD 30 0.00000000 Traco Power TMR 2E (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2358 EAR99 8504.40.9580 10 2 W 1 400mA 36V 73% 5V - - - 1 kV
TMR 2-4823WI Traco Power TMR 2-4823WI 20.2500
RFQ
ECAD 7 0.00000000 Traco Power TMR 2WI (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.02" L x 0.37" W x 0.49" H (26.0mm x 9.3mm x 12.5mm) Through Hole 9-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2361 EAR99 8504.40.9580 10 2 W 2 65mA, 65mA 18V 76% 15V -15V - - 1.5 kV
TMR 3-1212 Traco Power TMR 3-1212 21.5200
RFQ
ECAD 303 0.00000000 Traco Power TMR 3 (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2366 EAR99 8504.40.9580 10 3 W 1 250mA 9V 83% 12V - - - 1.6 kV
TMR 3-2423WI Traco Power TMR 3-2423WI 25.6000
RFQ
ECAD 631 0.00000000 Traco Power TMR 3WI (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2378 EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 9V 81% 15V -15V - - 1.6 kV
TMR 6-2412WI Traco Power TMR 6-2412WI 26.1200
RFQ
ECAD 3 0.00000000 Traco Power TMR 6WI (6W) Tube Active -40°C ~ 71°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2397 EAR99 8504.40.9580 10 6 W 1 500mA 9V 87% 12V - - - 1.6 kV
TMR 6-2421 Traco Power TMR 6-2421 24.7600
RFQ
ECAD 135 0.00000000 Traco Power TMR 6 (6W) Tube Active -40°C ~ 65°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2399 EAR99 8504.40.9580 10 6 W 2 600mA, 600mA 18V 82% 5V -5V - - 1.6 kV
TMR 6-2421WI Traco Power TMR 6-2421WI 27.9400
RFQ
ECAD 84 0.00000000 Traco Power TMR 6WI (6W) Tube Active -40°C ~ 71°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2400 EAR99 8504.40.9580 10 6 W 2 600mA, 600mA 9V 84% 5V -5V - - 1.6 kV
TMR 6-2423WI Traco Power TMR 6-2423WI 27.6800
RFQ
ECAD 512 0.00000000 Traco Power TMR 6WI (6W) Tube Active -40°C ~ 71°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2402 EAR99 8504.40.9580 10 6 W 2 200mA, 200mA 9V 87% 15V -15V - - 1.6 kV
TMV 2405SHI Traco Power TMV 2405SHI 9.6200
RFQ
ECAD 3 0.00000000 Traco Power TMV-HI (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 2405 26.4V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2409 EAR99 8504.40.9580 10 1 W 1 200mA 24V 70% 5V - - - 5.2 kV
TOS 06-05SIL Traco Power TOS 06-05SIL 20.9000
RFQ
ECAD 5505 0.00000000 Traco Power TOS Tube Active -40°C ~ 85°C ITE (Commercial) 0.90" L x 0.23" W x 0.40" H (22.9mm x 6.0mm x 10.2mm) Through Hole 5-SIP Module Non-Isolated PoL Module Remote On/Off, OCP, OTP, SCP TOS 06 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2412 EAR99 8504.40.9580 5 20 W 1 6A 2.4V 94% 0.75 ~ 3.3V - - -
TRA 3-0511 Traco Power TRA 3-0511 12.2800
RFQ
ECAD 6573 0.00000000 Traco Power TRA 1 (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TRA 3 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2420 EAR99 8504.40.9580 10 3 W 1 600mA 4.5V 83% 5V - - - 1 kV
TSR 2-24150 Traco Power TSR 2-24150 13.4500
RFQ
ECAD 183 0.00000000 Traco Power TSR 2 Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.55" L x 0.30" W x 0.40" H (14.0mm x 7.5mm x 10.1mm) Through Hole 3-SIP Module Linear Regulator Replacement OCP, SCP TSR 2 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2425 EAR99 8504.40.9580 10 30 W 1 2A 18V 96% 15V - - -
TMR 3-4810WIR Traco Power TMR 3-4810WIR 27.2200
RFQ
ECAD 8 0.00000000 Traco Power TMR 3WIR (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, SCP TMR 3 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1995 EAR99 8504.40.9580 10 2.3 W 1 700mA 18V 75% 3.3V - - - 3 kV
TMR 3-7212WIR Traco Power TMR 3-7212WIR 29.6200
RFQ
ECAD 454 0.00000000 Traco Power TMR 3WIR (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, SCP TMR 3 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2006 EAR99 8504.40.9580 10 3 W 1 250mA 43V 82% 12V - - - 3 kV
TMR 3-7215WIR Traco Power TMR 3-7215WIR 29.9000
RFQ
ECAD 3521 0.00000000 Traco Power TMR 3WIR (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, SCP TMR 3 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2008 EAR99 8504.40.9580 10 3 W 1 125mA 43V 83% 24V - - - 3 kV
TMR 6-2413WIR Traco Power TMR 6-2413WIR 32.0700
RFQ
ECAD 10 0.00000000 Traco Power TMR 6WIR (6W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, OCP, SCP TMR 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2016 EAR99 8504.40.9580 10 6 W 1 400mA 9V 88% 15V - - - 3 kV
TMV 1212S Traco Power TMV 1212S 6.0600
RFQ
ECAD 58 0.00000000 Traco Power TMV (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.40" H (19.5mm x 6.1mm x 10.2mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 1212 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2509 EAR99 8504.40.9580 10 1 W 1 84mA 12V 78% 12V - - - 3 kV
TEL 2-2413 Traco Power TEL 2-2413 13.5800
RFQ
ECAD 196 0.00000000 Traco Power TEL 2 (2W) Tube Not For New Designs -40°C ~ 75°C ITE (Commercial) 0.94" L x 0.54" W x 0.31" H (23.8mm x 13.7mm x 8.0mm) Through Hole 16-DIP Module, 6 Leads Isolated Module SCP TEL 2 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2531 EAR99 8504.40.9580 10 2 W 1 135mA 18V 81% 15V - - - 1.5 kV
TEL 2-2423 Traco Power TEL 2-2423 14.5000
RFQ
ECAD 20 0.00000000 Traco Power TEL 2 (2W) Tube Not For New Designs -40°C ~ 75°C ITE (Commercial) 0.94" L x 0.54" W x 0.31" H (23.8mm x 13.7mm x 8.0mm) Through Hole 16-DIP Module, 6 Leads Isolated Module SCP TEL 2 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2533 EAR99 8504.40.9580 10 2 W 2 65mA, 65mA 18V 80% 15V -15V - - 1.5 kV
TEL 2-4811 Traco Power TEL 2-4811 16.3200
RFQ
ECAD 3 0.00000000 Traco Power TEL 2 (2W) Tube Not For New Designs -40°C ~ 75°C ITE (Commercial) 0.94" L x 0.54" W x 0.31" H (23.8mm x 13.7mm x 8.0mm) Through Hole 16-DIP Module, 6 Leads Isolated Module SCP TEL 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2534 EAR99 8504.40.9580 10 2 W 1 400mA 36V 73% 5V - - - 1.5 kV
TEN 3-0511 Traco Power TEN 3-0511 18.9000
RFQ
ECAD 14 0.00000000 Traco Power TEN 3 (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 3 CB, cCSAus 9V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2551 EAR99 8504.40.9580 10 2.5 W 1 500mA 4.5V 73% 5V - - - 1.5 kV
TEN 3-2411WI Traco Power TEN 3-2411WI 22.3700
RFQ
ECAD 76 0.00000000 Traco Power TEN 3WI (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.79" W x 0.40" H (32.0mm x 20.0mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 3 CB, cCSAus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2552 EAR99 8504.40.9580 10 3 W 1 600mA 9V 79% 5V - - - 1.5 kV
TEN 6-2411WIN Traco Power TEN 6-2411WIN 22.7700
RFQ
ECAD 4741 0.00000000 Traco Power TEN 6WIN (6W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, SCP TEN 6 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2565 EAR99 8504.40.9580 10 6 W 1 1.2A 9V 80% 5V - - - 1.5 kV
TEN 8-7222WI Traco Power TEN 8-7222WI 50.0900
RFQ
ECAD 25 0.00000000 Traco Power TEN 8WI (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 8 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2577 EAR99 8504.40.9580 10 8 W 2 333mA, 333mA 43V 85% 12V -12V - - 1.5 kV
TMR 1222 Traco Power TMR 1222 16.7500
RFQ
ECAD 3 0.00000000 Traco Power TMR 2 (2W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 12 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2593 EAR99 8504.40.9580 10 2 W 2 85mA, 85mA 9V 83% 12V -12V - - 1.5 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse