Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
THD 12-4812 Traco Power THD 12-4812 39.1700
RFQ
ECAD 7335 0.00000000 Traco Power THD 12 (12W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 8 Leads Isolated Module Remote On/Off, OVP, SCP, UVLO THD 12 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1607 EAR99 8504.40.9580 10 12 W 1 1A 36V 87% 12V - - - 1.5 kV
THD 15-2421WIN Traco Power THD 15-2421WIN 60.7700
RFQ
ECAD 10 0.00000000 Traco Power THD 15WIN (15W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 8 Leads Isolated Module Remote On/Off, OVP, SCP THD 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1611 EAR99 8504.40.9580 10 15 W 2 1.5A, 1.5A 9V 86% 5V -5V - - 1.5 kV
THL 10-2410WI Traco Power THL 10-2410WI 44.8400
RFQ
ECAD 10 0.00000000 Traco Power THL 10WI (10W) Tube Not For New Designs -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module, 5 Leads Isolated Module Remote On/Off, SCP THL 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1613 EAR99 8504.40.9580 10 7.3 W 1 2.2A 9V 86% 3.3V - - - 1.5 kV
THL 10-2415WI Traco Power THL 10-2415WI 36.0200
RFQ
ECAD 11 0.00000000 Traco Power THL 10WI (10W) Tube Not For New Designs -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module, 5 Leads Isolated Module Remote On/Off, SCP THL 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1615 EAR99 8504.40.9580 10 9.8 W 1 410mA 9V 86% 24V - - - 1.5 kV
THL 10-2422WI Traco Power THL 10-2422WI 36.4560
RFQ
ECAD 1166 0.00000000 Traco Power THL 10WI (10W) Tube Not For New Designs -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module, 5 Leads Isolated Module Remote On/Off, SCP THL 10 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1616 EAR99 8504.40.9580 10 9.8 W 2 410mA, 410mA 9V 86% 12V -12V - - 1.5 kV
THL 20-2415WI Traco Power THL 20-2415WI 57.4400
RFQ
ECAD 11 0.00000000 Traco Power THL 20WI (20W) Tube Not For New Designs -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, SCP THL 20 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1617 EAR99 8504.40.9580 10 20 W 1 835mA 9V 88% 24V - - - 1.5 kV
THL 20-4811WI Traco Power THL 20-4811WI 57.4400
RFQ
ECAD 8185 0.00000000 Traco Power THL 20WI (20W) Tube Not For New Designs -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, SCP THL 20 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1618 EAR99 8504.40.9580 10 20 W 1 4A 18V 89% 5V - - - 1.5 kV
THM 15-1215 Traco Power THM 15-1215 59.7900
RFQ
ECAD 8 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1629 EAR99 8504.40.9580 10 15 W 1 625mA 9V 89% 24V - - - 5 kV
THM 15-1222 Traco Power THM 15-1222 61.8010
RFQ
ECAD 2229 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1631 EAR99 8504.40.9580 10 15 W 2 625mA, 625mA 9V 89% 12V -12V - - 5 kV
THM 15-1223 Traco Power THM 15-1223 62.7800
RFQ
ECAD 3 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1632 EAR99 8504.40.9580 10 15 W 2 500mA, 500mA 9V 89% 15V -15V - - 5 kV
THM 15-2421 Traco Power THM 15-2421 65.8400
RFQ
ECAD 1657 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1637 EAR99 8504.40.9580 10 15 W 2 1.5A, 1.5A 18V 86% 5V -5V - - 5 kV
THM 15-2422 Traco Power THM 15-2422 61.8010
RFQ
ECAD 4582 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1638 EAR99 8504.40.9580 10 15 W 2 625mA, 625mA 18V 90% 12V -12V - - 5 kV
THM 15-2423 Traco Power THM 15-2423 63.3800
RFQ
ECAD 16 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1639 EAR99 8504.40.9580 10 15 W 2 500mA, 500mA 18V 90% 15V -15V - - 5 kV
THM 15-4812 Traco Power THM 15-4812 58.8570
RFQ
ECAD 6007 0.00000000 Traco Power THM 15 (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1641 EAR99 8504.40.9580 10 15 W 1 1.25A 36V 88% 12V - - - 5 kV
THM 20-1213 Traco Power THM 20-1213 69.3500
RFQ
ECAD 10 0.00000000 Traco Power THM 20 (20W) Tube Active -40°C ~ 80°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 20 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1649 EAR99 8504.40.9580 10 20 W 1 1.33A 9V 88.5% 15V - - - 5 kV
THM 20-1221 Traco Power THM 20-1221 75.6700
RFQ
ECAD 5 0.00000000 Traco Power THM 20 (20W) Tube Active -40°C ~ 80°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 20 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1651 EAR99 8504.40.9580 10 20 W 2 2A, 2A 9V 86% 5V -5V - - 5 kV
THM 20-1222 Traco Power THM 20-1222 71.6900
RFQ
ECAD 1676 0.00000000 Traco Power THM 20 (20W) Tube Active -40°C ~ 80°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 20 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1652 EAR99 8504.40.9580 10 20 W 2 833mA, 833mA 9V 89% 12V -12V - - 5 kV
THM 20-2415 Traco Power THM 20-2415 69.3500
RFQ
ECAD 8201 0.00000000 Traco Power THM 20 (20W) Tube Active -40°C ~ 80°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 20 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1657 EAR99 8504.40.9580 10 20 W 1 833mA 18V 90% 24V - - - 5 kV
THM 30-1215 Traco Power THM 30-1215 84.6300
RFQ
ECAD 1732 0.00000000 Traco Power THM 30 (30W) Tube Active -40°C ~ 80°C (With Derating) Medical 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 30 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1671 EAR99 8504.40.9580 10 30 W 1 1.25A 9V 89% 24V - - - 5 kV
THM 30-2421 Traco Power THM 30-2421 96.8300
RFQ
ECAD 2 0.00000000 Traco Power THM 30 (30W) Tube Active -40°C ~ 80°C (With Derating) Medical 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 30 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1679 EAR99 8504.40.9580 10 30 W 2 3A, 3A 18V 86% 5V -5V - - 5 kV
THM 30-4821 Traco Power THM 30-4821 96.8300
RFQ
ECAD 1056 0.00000000 Traco Power THM 30 (30W) Tube Active -40°C ~ 80°C (With Derating) Medical 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 30 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1686 EAR99 8504.40.9580 10 30 W 2 3A, 3A 36V 86.5% 5V -5V - - 5 kV
THN 15-2412WIR Traco Power THN 15-2412WIR 51.3200
RFQ
ECAD 28 0.00000000 Traco Power THN 15WIR (15W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO THN 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1694 EAR99 8504.40.9580 10 16 W 1 1.3A 9V 89% 12V - - - 3 kV
THN 20-2415WI Traco Power THN 20-2415WI 51.3400
RFQ
ECAD 266 0.00000000 Traco Power THN 20WI (20W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 20 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1700 EAR99 8504.40.9580 10 20 W 1 833mA 9V 91% 24V - - - 1.5 kV
THN 20-4811WI Traco Power THN 20-4811WI 50.8500
RFQ
ECAD 1 0.00000000 Traco Power THN 20WI (20W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 20 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1703 EAR99 8504.40.9580 10 20 W 1 4A 18V 89% 5V - - - 1.5 kV
THN 20-4813WI Traco Power THN 20-4813WI 50.8500
RFQ
ECAD 25 0.00000000 Traco Power THN 20WI (20W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP THN 20 CB, cURus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1704 EAR99 8504.40.9580 10 20 W 1 1.33A 18V 90% 15V - - - 1.5 kV
THN 30-1212 Traco Power THN 30-1212 73.4400
RFQ
ECAD 2037 0.00000000 Traco Power THN 30 (30W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP THN 30 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1705 EAR99 8504.40.9580 10 30 W 1 2.5A 9V 89% 12V - - - 1.5 kV
THN 30-2410WI Traco Power THN 30-2410WI 83.9000
RFQ
ECAD 252 0.00000000 Traco Power THN 30WI (30W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO THN 30 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1706 EAR99 8504.40.9580 10 23 W 1 7A 9V 86% 3.3V - - - 1.5 kV
THN 30-2413WI Traco Power THN 30-2413WI 80.0400
RFQ
ECAD 42 0.00000000 Traco Power THN 30WI (30W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO THN 30 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1708 EAR99 8504.40.9580 10 30 W 1 2A 9V 89% 15V - - - 1.5 kV
THP 3-7223 Traco Power THP 3-7223 65.4200
RFQ
ECAD 20 0.00000000 Traco Power THP 3 (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Medical 1.25" L x 0.80" W x 0.41" H (31.8mm x 20.3mm x 10.5mm) Through Hole 24-DIP Module, 5 Leads Isolated Module SCP THP 3 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1715 EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 36V 83% 15V -15V - - 3 kV
TIM 2-0913 Traco Power TIM 2-0913 28.6300
RFQ
ECAD 10 0.00000000 Traco Power TIM 2 (2W) Tube Active -40°C ~ 95°C (With Derating) Medical 0.96" L x 0.57" W x 0.40" H (24.3mm x 14.4mm x 10.2mm) Through Hole 16-DIP Module, 7 Leads Isolated Module Remote On/Off, OVP, SCP TIM 2 12V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1719 EAR99 8504.40.9580 10 2 W 1 134mA 4.5V 81% 15V - - - 5 kV