Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
THN 15-4812WIR Traco Power THN 15-4812WIR 54.0200
RFQ
ECAD 8 0.00000000 Traco Power THN 15WIR (15W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO THN 15 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 16 W 1 1.3A 18V 89% 12V - - - 3 kV
TEN 20-4811WIR Traco Power TEN 20-4811WIR 85.1600
RFQ
ECAD 10 0.00000000 Traco Power TEN 20WIR (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP TEN 20 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 20 W 1 4A 18V 88% 5V - - - 2.25 kV
TEN 20-4822 Traco Power TEN 20-4822 70.8800
RFQ
ECAD 8 0.00000000 Traco Power TEN 20 (20W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module SCP TEN 20 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 20 W 2 835mA, 835mA 18V 89% 12V -12V - - 1.5 kV
TEN 20-4823WIR Traco Power TEN 20-4823WIR 80.7030
RFQ
ECAD 9409 0.00000000 Traco Power TEN 20WIR (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP TEN 20 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 20 W 2 667mA, 667mA 18V 89% 15V -15V - - 2.25 kV
TEN 25-2422WI Traco Power TEN 25-2422WI 61.2200
RFQ
ECAD 5684 0.00000000 Traco Power TEN 25WI (30W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.60" W x 0.37" H (50.8mm x 40.6mm x 9.3mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO TEN 25 40V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 30 W 2 1.25A, 1.25A 10V 89% 12V -12V - - 1.5 kV
TEN 25-4812WI Traco Power TEN 25-4812WI 59.4300
RFQ
ECAD 5 0.00000000 Traco Power TEN 25WI (30W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.60" W x 0.37" H (50.8mm x 40.6mm x 9.3mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO TEN 25 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 30 W 1 2.5A 18V 89% 12V - - - 1.5 kV
TEN 25-4813WI Traco Power TEN 25-4813WI 59.4300
RFQ
ECAD 4 0.00000000 Traco Power TEN 25WI (30W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.60" W x 0.37" H (50.8mm x 40.6mm x 9.3mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO TEN 25 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 30 W 1 2A 18V 89% 15V - - - 1.5 kV
TEN 30-1210 Traco Power TEN 30-1210 69.4200
RFQ
ECAD 20 0.00000000 Traco Power TEN 30 (30W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 30 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 26 W 1 8A 9V 85% 3.3V - - - 1.5 kV
TEN 30-1222 Traco Power TEN 30-1222 73.2500
RFQ
ECAD 1687 0.00000000 Traco Power TEN 30 (30W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 30 18V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 30 W 2 1.25A, 1.25A 9V 87% 12V -12V - - 1.5 kV
TEN 30-2422 Traco Power TEN 30-2422 73.9500
RFQ
ECAD 8 0.00000000 Traco Power TEN 30 (30W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 30 36V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 30 W 2 1.25A, 1.25A 18V 89% 12V -12V - - 1.5 kV
TEN 30-4810 Traco Power TEN 30-4810 68.3330
RFQ
ECAD 8347 0.00000000 Traco Power TEN 30 (30W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 30 75V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 25 W 1 7.5A 36V 87% 3.3V - - - 1.5 kV
TEN 3-2413WIN Traco Power TEN 3-2413WIN 14.9300
RFQ
ECAD 73 0.00000000 Traco Power TEN 3WIN (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module SCP TEN 3 CB, cCSAus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 200mA 9V 83% 15V - - - 1.5 kV
TEN 3-2423WIN Traco Power TEN 3-2423WIN 17.1900
RFQ
ECAD 7765 0.00000000 Traco Power TEN 3WIN (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 8 Leads Isolated Module SCP TEN 3 CB, cCSAus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 9V 82% 15V -15V - - 1.5 kV
TEN 3-4821N Traco Power TEN 3-4821N 16.1580
RFQ
ECAD 8793 0.00000000 Traco Power TEN 3N (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 8 Leads Isolated Module SCP TEN 3 CB, cCSAus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2.5 W 2 250mA, 250mA 36V 80% 5V -5V - - 1.5 kV
TEN 3-4821WIN Traco Power TEN 3-4821WIN 16.9260
RFQ
ECAD 6411 0.00000000 Traco Power TEN 3WIN (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 8 Leads Isolated Module SCP TEN 3 CB, cCSAus 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2.5 W 2 250mA, 250mA 18V 80% 5V -5V - - 1.5 kV
TEN 40-1210 Traco Power TEN 40-1210 90.9300
RFQ
ECAD 15 0.00000000 Traco Power TEN 40 (40W) Tube Active -40°C ~ 75°C ITE (Commercial) 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 40 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 26 W 1 8A 9V 86% 3.3V - - - 1.5 kV
TEN 40-1211 Traco Power TEN 40-1211 90.9300
RFQ
ECAD 5 0.00000000 Traco Power TEN 40 (40W) Tube Active -40°C ~ 75°C ITE (Commercial) 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 40 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 40 W 1 8A 9V 86% 5V - - - 1.5 kV
TEN 40-1211N Traco Power TEN 40-1211N 74.3400
RFQ
ECAD 8121 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 8A 9V 89% 5V - - - 1.5 kV
TEN 40-2410WI Traco Power TEN 40-2410WI 101.3300
RFQ
ECAD 5 0.00000000 Traco Power TEN 40WI (40W) Tube Active -40°C ~ 85°C ITE (Commercial) 2.00" L x 1.10" W x 0.40" H (50.8mm x 27.9mm x 10.2mm) Through Hole 8-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 40 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 33 W 1 10A 9V 86% 3.3V - - - 1.5 kV
TEN 40-2413WIN Traco Power TEN 40-2413WIN 86.7300
RFQ
ECAD 5 0.00000000 Traco Power TEN 40WIN (40W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.43" H (50.8mm x 25.4mm x 11.0mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP TEN 40 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 2.67A 9V 89% 15V - - - 1.5 kV
TEN 40-2423WIN Traco Power TEN 40-2423WIN 88.9400
RFQ
ECAD 7 0.00000000 Traco Power TEN 40WIN (40W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.43" H (50.8mm x 25.4mm x 11.0mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP TEN 40 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 2 1.33A, 1.33A 9V 88% 15V -15V - - 1.5 kV
TEN 40-4811N Traco Power TEN 40-4811N 74.3400
RFQ
ECAD 10 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 8A 36V 91% 5V - - - 1.5 kV
TEN 40-4812 Traco Power TEN 40-4812 90.9300
RFQ
ECAD 5872 0.00000000 Traco Power TEN 40 (40W) Tube Active -40°C ~ 75°C ITE (Commercial) 2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 40 W 1 3.35A 36V 89% 12V - - - 1.5 kV
TEN 40-4812WIN Traco Power TEN 40-4812WIN 86.7300
RFQ
ECAD 1704 0.00000000 Traco Power TEN 40WIN (40W) Tube Active -40°C ~ 75°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 3.33A 18V 90% 12V - - - 1.5 kV
TEN 40-4813N Traco Power TEN 40-4813N 74.3400
RFQ
ECAD 10 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 2.67A 36V 92% 15V - - - 1.5 kV
TEN 40-4813WIR Traco Power TEN 40-4813WIR 102.5200
RFQ
ECAD 17 0.00000000 Traco Power TEN 40WIR (40W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 2.666A 18V 92% 15V - - - 1.6 kV
TEN 40-4815N Traco Power TEN 40-4815N 76.1300
RFQ
ECAD 8 0.00000000 Traco Power TEN 40N (40W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 1 1.67A 36V 91% 24V - - - 1.5 kV
TEN 40-4822WI Traco Power TEN 40-4822WI 106.8900
RFQ
ECAD 8914 0.00000000 Traco Power TEN 40WI (40W) Tube Active -40°C ~ 85°C ITE (Commercial) 2.00" L x 1.10" W x 0.40" H (50.8mm x 27.9mm x 10.2mm) Through Hole 8-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 40 W 2 1.65A, 1.65A 18V 86% 12V -12V - - 1.5 kV
TEN 40-4822WIR Traco Power TEN 40-4822WIR 113.8600
RFQ
ECAD 10 0.00000000 Traco Power TEN 40WIR (40W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 40 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 40 W 2 1.666A, 1.666A 18V 90% 12V -12V - - 1.6 kV
TEN 40-7210WIR Traco Power TEN 40-7210WIR 116.2090
RFQ
ECAD 9510 0.00000000 Traco Power TEN 40WIR (40W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 40 160V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 33 W 1 10A 43V 88% 3.3V - - - 1.6 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse