Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Voltage - Input (Max) DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
REM10-053.3S/A Recom Power REM10-053.3S/A 85.4100
RFQ
ECAD 5954 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-053.3 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000288 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2.5A 4.5V 80% 3.3V - - - 5 kV
REM10-123.3S/A Recom Power REM10-123.3S/A 85.4100
RFQ
ECAD 2272 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-123.3 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000291 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2.5A 9V 83% 3.3V - - - 5 kV
REM10-123.3S/A/CTRL Recom Power REM10-123.3S/A/CTRL 89.7200
RFQ
ECAD 7690 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-123.3 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000292 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2.5A 9V 83% 3.3V - - - 5 kV
REM10-123.3S/C Recom Power REM10-123.3S/C 85.4100
RFQ
ECAD 1554 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-123.3 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000293 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2.5A 9V 83% 3.3V - - - 5 kV
REM10-243.3S/A Recom Power REM10-243.3S/A 85.4100
RFQ
ECAD 3285 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-243.3 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000294 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2.5A 18V 83% 3.3V - - - 5 kV
REM10-483.3S/A/CTRL Recom Power REM10-483.3S/A/CTRL 89.7200
RFQ
ECAD 4431 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-483.3 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000298 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2.5A 36V 82.5% 3.3V - - - 5 kV
REM10-0505S/A/CTRL Recom Power REM10-0505S/A/CTRL 89.7200
RFQ
ECAD 7920 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0505 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000301 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2A 4.5V 84% 5V - - - 5 kV
REM10-0505S/C Recom Power REM10-0505S/C 85.4100
RFQ
ECAD 1689 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0505 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000302 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2A 4.5V 84% 5V - - - 5 kV
REM10-2405S/A Recom Power REM10-2405S/A 85.4100
RFQ
ECAD 93 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2405 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2A 18V 86.5% 5V - - - 5 kV
REM10-2405S/A/CTRL Recom Power REM10-2405S/A/CTRL 89.7200
RFQ
ECAD 9877 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2405 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000307 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2A 18V 86.5% 5V - - - 5 kV
REM10-4805S/A Recom Power REM10-4805S/A 85.4100
RFQ
ECAD 3745 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-4805 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000309 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2A 36V 86.5% 5V - - - 5 kV
REM10-4805S/A/CTRL Recom Power REM10-4805S/A/CTRL 89.7200
RFQ
ECAD 8541 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-4805 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000310 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 2A 36V 86.5% 5V - - - 5 kV
REM10-0512S/A Recom Power REM10-0512S/A 85.5800
RFQ
ECAD 2490 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0512 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 830mA 4.5V 86.5% 12V - - - 5 kV
REM10-0512S/A/CTRL Recom Power REM10-0512S/A/CTRL 89.7200
RFQ
ECAD 1806 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0512 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000313 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 830mA 4.5V 86.5% 12V - - - 5 kV
REM10-0512S/C Recom Power REM10-0512S/C 85.4100
RFQ
ECAD 8165 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0512 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000314 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 830mA 4.5V 86.5% 12V - - - 5 kV
REM10-4812S/A Recom Power REM10-4812S/A 85.4100
RFQ
ECAD 45 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-4812 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 830mA 36V 89% 12V - - - 5 kV
REM10-1215S/A/CTRL Recom Power REM10-1215S/A/CTRL 89.7200
RFQ
ECAD 2960 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-1215 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000328 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 670mA 9V 89% 15V - - - 5 kV
REM10-2415S/A/CTRL Recom Power REM10-2415S/A/CTRL 89.7200
RFQ
ECAD 9846 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2415 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000331 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 670mA 18V 89% 15V - - - 5 kV
REM10-4815S/A/CTRL Recom Power REM10-4815S/A/CTRL 89.7200
RFQ
ECAD 7257 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-4815 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000334 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 670mA 36V 89% 15V - - - 5 kV
REM10-4815S/C Recom Power REM10-4815S/C 85.4100
RFQ
ECAD 9669 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-4815 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000335 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 670mA 36V 89% 15V - - - 5 kV
REM10-2424S/A Recom Power REM10-2424S/A 85.4100
RFQ
ECAD 2939 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2424 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000342 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 416mA 18V 89% 24V - - - 5 kV
REM10-4824S/C Recom Power REM10-4824S/C 85.4100
RFQ
ECAD 3192 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 5 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-4824 75V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000347 EAR99 8504.40.9580 7 10 W 1 Enable, Active Low 416mA 36V 88% 24V - - - 5 kV
REM10-0512D/A/CTRL Recom Power REM10-0512D/A/CTRL 98.6800
RFQ
ECAD 7641 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0512 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000361 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 416mA 4.5V 85.5% 12V -12V - - 5 kV
REM10-1212D/A Recom Power REM10-1212D/A 93.9600
RFQ
ECAD 3590 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-1212 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 416mA, 416mA 9V 89% 12V -12V - - 5 kV
REM10-1212D/C Recom Power REM10-1212D/C 93.9600
RFQ
ECAD 1357 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-1212 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000365 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 416mA, 416mA 9V 89% 12V -12V - - 5 kV
REM10-2412D/A Recom Power REM10-2412D/A 93.9600
RFQ
ECAD 4184 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2412 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000366 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 416mA, 416mA 18V 89% 12V -12V - - 5 kV
REM10-2412D/A/CTRL Recom Power REM10-2412D/A/CTRL 98.6800
RFQ
ECAD 4736 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2412 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000367 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 416mA, 416mA 18V 89% 12V -12V - - 5 kV
REM10-0515D/C Recom Power REM10-0515D/C 93.9600
RFQ
ECAD 6894 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-0515 9V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000374 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 333mA, 333mA 4.5V 86.5% 15V -15V - - 5 kV
REM10-1215D/C Recom Power REM10-1215D/C 93.9600
RFQ
ECAD 5505 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 6 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-1215 18V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000377 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 333mA, 333mA 9V 88% 15V -15V - - 5 kV
REM10-2415D/A/CTRL Recom Power REM10-2415D/A/CTRL 98.6800
RFQ
ECAD 2435 0.00000000 Recom Power MEDLINE REM10 (10W) Tube Active -40°C ~ 105°C ITE (Commercial), Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM10-2415 36V download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000379 EAR99 8504.40.9580 7 10 W 2 Enable, Active Low 333mA, 333mA 18V 89% 15V -15V - - 5 kV