Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation
REM5E-0505D/R10/A Recom Power REM5E-0505D/R10/A 55.2900
RFQ
ECAD 1478 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-0505 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001187 EAR99 8504.40.9580 15 5 W 2 500mA, 500mA 4.5V 75% 5V -5V - - 10 kV
REM5E-0505D/R8/A/X1 Recom Power REM5E-0505D/R8/A/X1 50.7000
RFQ
ECAD 2967 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-0505 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001183 EAR99 8504.40.9580 15 5 W 2 500mA, 500mA 4.5V 75% 5V -5V - - 8 kV
REM5E-0505S/R10/A/X1 Recom Power REM5E-0505S/R10/A/X1 55.2900
RFQ
ECAD 2484 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-0505 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000595 EAR99 8504.40.9580 15 5 W 1 1A 4.5V 75% 5V - - - 10 kV
REM5E-0505S/R8/A/CTRL/X1 Recom Power REM5E-0505S/R8/A/CTRL/X1 50.7000
RFQ
ECAD 6588 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-0505 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000590 EAR99 8504.40.9580 15 5 W 1 1A 4.5V 75% 5V - - - 8 kV
REM5E-0509D/R10/A Recom Power REM5E-0509D/R10/A 55.2900
RFQ
ECAD 3469 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-0509 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001235 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 4.5V 80% 9V -9V - - 10 kV
REM5E-0509D/R10/A/X1 Recom Power REM5E-0509D/R10/A/X1 60.8200
RFQ
ECAD 8470 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-0509 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001237 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 4.5V 80% 9V -9V - - 10 kV
REM5E-0509D/R8/A/CTRL/X1 Recom Power REM5E-0509D/R8/A/CTRL/X1 55.7600
RFQ
ECAD 9777 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-0509 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001232 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 4.5V 80% 9V -9V - - 8 kV
REM5E-0509S/R10/A Recom Power REM5E-0509S/R10/A 50.2700
RFQ
ECAD 4345 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-0509 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001043 EAR99 8504.40.9580 15 5 W 1 556mA 4.5V 80% 9V - - - 10 kV
REM5E-0509S/R8/A/CTRL Recom Power REM5E-0509S/R8/A/CTRL 46.0800
RFQ
ECAD 1657 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-0509 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001038 EAR99 8504.40.9580 15 5 W 1 556mA 4.5V 80% 9V - - - 8 kV
REM5E-0512D/R8/A Recom Power REM5E-0512D/R8/A 46.0800
RFQ
ECAD 2311 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-0512 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001277 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 4.5V 81% 12V -12V - - 8 kV
REM5E-0512D/R8/A/X1 Recom Power REM5E-0512D/R8/A/X1 50.7000
RFQ
ECAD 7986 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-0512 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001279 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 4.5V 81% 12V -12V - - 8 kV
REM5E-0512S/R10/A/X1 Recom Power REM5E-0512S/R10/A/X1 55.2900
RFQ
ECAD 7995 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-0512 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000643 EAR99 8504.40.9580 15 5 W 1 417mA 4.5V 81% 12V - - - 10 kV
REM5E-0515D/R10/A/X1 Recom Power REM5E-0515D/R10/A/X1 60.8200
RFQ
ECAD 5378 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-0515 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001333 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 4.5V 82% 15V -15V - - 10 kV
REM5E-0515S/R10/A/CTRL Recom Power REM5E-0515S/R10/A/CTRL 55.2900
RFQ
ECAD 3282 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-0515 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001092 EAR99 8504.40.9580 15 5 W 1 333mA 4.5V 81% 15V - - - 10 kV
REM5E-0524S/R10/A/CTRL Recom Power REM5E-0524S/R10/A/CTRL 55.2900
RFQ
ECAD 9261 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-0524 CB, cURus 9V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001140 EAR99 8504.40.9580 15 5 W 1 208mA 4.5V 82% 24V - - - 10 kV
REM5E-1205S/R10/A/CTRL Recom Power REM5E-1205S/R10/A/CTRL 52.5300
RFQ
ECAD 2616 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-1205 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000606 EAR99 8504.40.9580 15 5 W 1 1A 9V 80% 5V - - - 10 kV
REM5E-1205S/R8/A/X1 Recom Power REM5E-1205S/R8/A/X1 43.7800
RFQ
ECAD 4868 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-1205 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51000601 EAR99 8504.40.9580 15 5 W 1 1A 9V 80% 5V - - - 8 kV
REM5E-1209D/R10/A/X1 Recom Power REM5E-1209D/R10/A/X1 57.8100
RFQ
ECAD 2466 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001249 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 9V 81% 9V -9V - - 10 kV
REM5E-1209D/R8/A Recom Power REM5E-1209D/R8/A 43.7800
RFQ
ECAD 6540 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001241 EAR99 8504.40.9580 15 5 W 2 277mA, 277mA 9V 81% 9V -9V - - 8 kV
REM5E-1209S/R10/A Recom Power REM5E-1209S/R10/A 47.7600
RFQ
ECAD 5991 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001055 EAR99 8504.40.9580 15 5 W 1 556mA 9V 81% 9V - - - 10 kV
REM5E-1209S/R10/A/CTRL Recom Power REM5E-1209S/R10/A/CTRL 52.5300
RFQ
ECAD 4379 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001056 EAR99 8504.40.9580 15 5 W 1 556mA 9V 81% 9V - - - 10 kV
REM5E-1209S/R10/A/X1 Recom Power REM5E-1209S/R10/A/X1 52.5300
RFQ
ECAD 4129 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-1209 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001057 EAR99 8504.40.9580 15 5 W 1 556mA 9V 81% 9V - - - 10 kV
REM5E-1212D/R8/A/CTRL Recom Power REM5E-1212D/R8/A/CTRL 48.1700
RFQ
ECAD 8482 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-1212 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001290 EAR99 8504.40.9580 15 5 W 2 208mA, 208mA 9V 82% 12V -12V - - 8 kV
REM5E-1215D/R10/A Recom Power REM5E-1215D/R10/A 52.5300
RFQ
ECAD 8719 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001343 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 9V 82% 15V -15V - - 10 kV
REM5E-1215D/R10/A/X1 Recom Power REM5E-1215D/R10/A/X1 57.8100
RFQ
ECAD 5695 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001345 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 9V 82% 15V -15V - - 10 kV
REM5E-1215D/R8/A Recom Power REM5E-1215D/R8/A 43.7800
RFQ
ECAD 6534 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP REM5E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001337 EAR99 8504.40.9580 15 5 W 2 166mA, 166mA 9V 82% 15V -15V - - 8 kV
REM5E-1215S/R10/A/CTRL/X1 Recom Power REM5E-1215S/R10/A/CTRL/X1 57.8100
RFQ
ECAD 5864 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001106 EAR99 8504.40.9580 15 5 W 1 333mA 9V 83% 15V - - - 10 kV
REM5E-1215S/R8/A/CTRL/X1 Recom Power REM5E-1215S/R8/A/CTRL/X1 48.1700
RFQ
ECAD 4065 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO REM5E-1215 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001100 EAR99 8504.40.9580 15 5 W 1 333mA 9V 83% 15V - - - 8 kV
REM5E-1224S/R10/A/CTRL Recom Power REM5E-1224S/R10/A/CTRL 52.5300
RFQ
ECAD 3436 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module Remote On/Off, OCP, OVP, SCP REM5E-1224 CB, cURus 18V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001152 EAR99 8504.40.9580 15 5 W 1 208mA 9V 83% 24V - - - 10 kV
REM5E-2405D/R8/A/X1 Recom Power REM5E-2405D/R8/A/X1 48.1700
RFQ
ECAD 9051 0.00000000 Recom Power MEDLINE REM5E (5W) Tube Active -40°C ~ 80°C Medical 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, OVP, SCP, UVLO REM5E-2405 CB, cURus 36V - ROHS3 Compliant 1 (Unlimited) REACH Unaffected 51001207 EAR99 8504.40.9580 15 5 W 2 500mA, 500mA 18V 81% 5V -5V - - 8 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse