Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Mounting Type | Features | Base Product Number | Termination Style | Weight | Voltage - Supply | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Function | Delay Time | Trip Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SE-325P | 1.0000 | 4823 | 0.00000000 | Littelfuse Inc. | SE-325 | Bulk | Active | -40°C ~ 60°C | Chassis Mount | Manual Reset | Screw Terminal | - | 120VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-325P | EAR99 | 8543.70.9860 | 1 | Ground Fault, Overvoltage | 0.1 ~ 2s | 0.5 ~ 4A | ||||
SE-325S | 1.0000 | 2046 | 0.00000000 | Littelfuse Inc. | SE-325 | Bulk | Active | -40°C ~ 60°C | Chassis Mount | Manual Reset | Screw Terminal | - | 120VAC | download | ROHS3 Compliant | Not Applicable | -1024-SE-325S | EAR99 | 8543.70.9860 | 1 | Ground Fault, Overvoltage | 0.1 ~ 2s | 0.5 ~ 4A | |||||
SE-325SNT | 2.0000 | 1220 | 0.00000000 | Littelfuse Inc. | SE-325 | Bulk | Active | -40°C ~ 60°C | Chassis Mount | Manual Reset | Screw Terminal | - | 120VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-325SNT | EAR99 | 8543.70.9860 | 1 | Ground Fault, Overvoltage | 0.1 ~ 2s | 0.5 ~ 4A | ||||
SE-330-00-01 | 3.0000 | 1 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120/240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330-00-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330-01-01 | 5.0000 | 6346 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120/240VAC/DC | download | ROHS3 Compliant | Not Applicable | -1024-SE-330-01-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | |||||
SE-330-04-00 | 4.0000 | 3444 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120/240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330-04-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330-05-00 | 4.0000 | 4236 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120/240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330-05-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330-05-01 | 4.0000 | 6549 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120/240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330-05-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330-22-10 | - | 1961 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Obsolete | download | ROHS3 Compliant | Not Applicable | EAR99 | 8543.70.9860 | 1 | |||||||||||||||
SE-330-23-01 | 5.0000 | 6888 | 0.00000000 | Littelfuse Inc. | SE-330 | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 48VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330-23-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330AU-03-01 | 4.0000 | 4312 | 0.00000000 | Littelfuse Inc. | SE-330AU | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 48VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330AU-03-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 0.5s | 0.125 ~ 30A | ||||
SE-330AU-20-00 | 3.0000 | 7317 | 0.00000000 | Littelfuse Inc. | SE-330AU | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120 ~ 240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330AU-20-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 0.5s | 0.125 ~ 30A | ||||
SE-330AU-21-01 | 5.0000 | 5856 | 0.00000000 | Littelfuse Inc. | SE-330AU | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 48VDC | download | ROHS3 Compliant | Not Applicable | -1024-SE-330AU-21-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 0.5s | 125mA ~ 30A | |||||
SE-330AU-23-01 | 5.0000 | 5901 | 0.00000000 | Littelfuse Inc. | SE-330AU | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120 ~ 240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330AU-23-01 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 0.5s | 0.125 ~ 30A | ||||
SE-330HV-04-00 | 5.0000 | 6823 | 0.00000000 | Littelfuse Inc. | SE-330HV | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120 ~ 240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330HV-04-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330HV-05-00 | 5.0000 | 3336 | 0.00000000 | Littelfuse Inc. | SE-330HV | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120 ~ 240VAC/DC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330HV-05-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330HV-07-00 | 5.0000 | 8689 | 0.00000000 | Littelfuse Inc. | SE-330HV | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 120 ~ 240VAC/DC | download | ROHS3 Compliant | Not Applicable | -1024-SE-330HV-07-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | |||||
SE-330HV-20-00 | 3.0000 | 2479 | 0.00000000 | Littelfuse Inc. | SE-330HV | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 48VDC | download | ROHS3 Compliant | Not Applicable | -1024-SE-330HV-20-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | |||||
SE-330HV-21-00 | 5.0000 | 1518 | 0.00000000 | Littelfuse Inc. | SE-330HV | Bulk | Active | -40°C ~ 60°C | Panel Mount | Harmonic Filtering, Manual Reset | Screw Terminal | - | 48VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-330HV-21-00 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.1 ~ 10s | 20 ~ 10000VAC | ||||
SE-330HV-22-00 | - | 7049 | 0.00000000 | Littelfuse Inc. | * | Bulk | Obsolete | download | ROHS3 Compliant | Not Applicable | EAR99 | 8543.70.9860 | 1 | |||||||||||||||
SE-330HV-22-01 | - | 7124 | 0.00000000 | Littelfuse Inc. | * | Bulk | Obsolete | download | ROHS3 Compliant | Not Applicable | EAR99 | 8543.70.9860 | 1 | |||||||||||||||
SE-601-0D-CC | 1.0000 | 1 | 0.00000000 | Littelfuse Inc. | SE-601 | Bulk | Active | -40°C ~ 85°C | Chassis Mount, DIN Rail | Manual Reset, Test Button | Screw Terminal | - | 12 ~ 24VDC | download | ROHS3 Compliant | Not Applicable | EAR99 | 8543.70.9860 | 1 | Ground Fault, Overcurrent | 0.5 ~ 2.5s | 0.1 ~ 0.2A | ||||||
SE-601-0T-CC | 1.0000 | 7884 | 0.00000000 | Littelfuse Inc. | - | Bulk | Active | -40°C ~ 60°C | Chassis Mount, DIN Rail | Manual Reset, Test Button | Screw Terminal | - | 48VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | -1024-SE-601-0T-CC | EAR99 | 8543.70.9860 | 1 | Ground Fault, Overcurrent | 0.05 ~ 2.5s | 1 ~ 20mA | ||||
SE-701-03 | 901.8900 | 4788 | 0.00000000 | Littelfuse Inc. | SE-701 | Bulk | Active | -40°C ~ 60°C | Chassis Mount, DIN Rail | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | Screw Terminal | - | 24VAC | download | ROHS3 Compliant | Not Applicable | -1024-SE-701-03 | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.05 ~ 2.5s | - | |||||
SE-701-0D-CC | 1.0000 | 3529 | 0.00000000 | Littelfuse Inc. | - | Bulk | Active | -40°C ~ 60°C | Chassis Mount, DIN Rail | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | Screw Terminal | - | 12 ~ 24VDC | download | ROHS3 Compliant | Not Applicable | -1024-SE-701-0D-CC | EAR99 | 8543.70.9860 | 1 | Ground Fault | 0.05 ~ 2.5s | - | |||||
SE-703-0D | - | 5168 | 0.00000000 | Littelfuse Inc. | * | Bulk | Obsolete | download | ROHS3 Compliant | Not Applicable | EAR99 | 8543.70.9860 | 1 | |||||||||||||||
M8100.0170 | - | 1262 | 0.00000000 | Littelfuse Inc. | * | Bulk | Obsolete | - | Not applicable | Not Applicable | -M8100.0170 | EAR99 | 8543.70.9860 | 1 | ||||||||||||||
K2CM-Q2LSA | 495.3000 | 2377 | 0.00000000 | Omron Automation and Safety | K2CM | Bulk | Active | -10°C ~ 60°C | Chassis Mount | Automatic Reset, Test Button | K2CM-Q2 | Screw Terminal | - | 200/220/240VAC | - | 1 (Unlimited) | K2CMQ2LSA | 0000.00.0000 | 1 | Overcurrent, Phase Loss, Phase Sequence | 2 ~ 40s | 2 ~ 8A | ||||||
K6EL-A100 | 230.9800 | 1324 | 0.00000000 | Omron Automation and Safety | K6EL | Bulk | Active | -10°C ~ 55°C | Socketable | Manual Reset, Test Button | Plug In, 11 Pin (Octal) | - | 100/110VAC, 200/220VAC | - | Not applicable | 1 (Unlimited) | K6ELA100 | 0000.00.0000 | 1 | Ground Fault | 0.3/0.8s | 0.1/0.2A | ||||||
H3RN-21-B DC24 | 91.8800 | 3000 | 0.00000000 | Omron Automation and Safety | * | Bulk | Active | H3RN-21 | - | 236-H3RN-21-B DC24 | 1 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse