SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Tolerance Operating Temperature Ratings Size / Dimension Height - Seated (Max) Mounting Type Package / Case Type Features Frequency - Self Resonant Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Current Rating (Amps) Shielding Material - Core Inductance Current - Saturation (Isat) DC Resistance (DCR) Q @ Freq Inductance Frequency - Test
TCK-154 Traco Power TCK-154 2.6000
RFQ
ECAD 4836 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.177" L x 0.158" W (4.50mm x 4.00mm) 0.146" (3.70mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.50.8000 10 1.15 A Unshielded - 4.7 µH - 109mOhm - 1 kHz
TCK-148 Traco Power TCK-148 2.3200
RFQ
ECAD 10 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.138" L x 0.122" W (3.50mm x 3.10mm) 0.102" (2.60mm) Surface Mount Nonstandard - - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.50.8000 10 250 mA Unshielded - 82 µH - 2.8Ohm - 1 kHz
TCK-166 Traco Power TCK-166 3.5550
RFQ
ECAD 5878 0.00000000 Traco Power - Bulk Active ±20% -55°C ~ 125°C - 0.394" L x 0.394" W (10.00mm x 10.00mm) 0.157" (4.00mm) Surface Mount Nonstandard - - - - download ROHS3 Compliant 1951-TCK-166 EAR99 8504.50.8000 10 9 A Unshielded - 8.2 µH - 27mOhm Max - 100 kHz
TCK-133 Traco Power TCK-133 3.6700
RFQ
ECAD 422 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.177" L x 0.157" W (4.50mm x 4.00mm) 0.146" (3.70mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1049 EAR99 8504.50.8000 10 370 mA Unshielded - 68 µH - 1.117Ohm - 100 kHz
TCK-070 Traco Power TCK-070 6.7600
RFQ
ECAD 9518 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.307" L x 0.276" W (7.80mm x 7.00mm) 0.224" (5.70mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1016 EAR99 8504.50.8000 10 2.6 A Unshielded - 10 µH - 40mOhm - 1 kHz
TCK-098 Traco Power TCK-098 6.6900
RFQ
ECAD 30 0.00000000 Traco Power - Strip Active ±20% -40°C ~ 125°C - 0.307" L x 0.276" W (7.80mm x 7.00mm) 0.224" (5.70mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1027 EAR99 8504.50.8000 10 1.5 A Unshielded - 22 µH - 110mOhm - 1 kHz
TCK-129 Traco Power TCK-129 3.5300
RFQ
ECAD 155 0.00000000 Traco Power - Bag Not For New Designs ±20% -40°C ~ 105°C - 0.177" L x 0.157" W (4.50mm x 4.00mm) 0.138" (3.50mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1045 EAR99 8504.50.8000 10 900 mA Unshielded - 6.8 µH - 132mOhm - 1 kHz
TCK-151 Traco Power TCK-151 3.2000
RFQ
ECAD 64 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.138" L x 0.118" W (3.50mm x 3.00mm) 0.102" (2.60mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1053 EAR99 8504.50.8000 10 1.5 A Unshielded - 4.7 µH - 150mOhm -
TCK-155 Traco Power TCK-155 2.8600
RFQ
ECAD 50 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.138" L x 0.122" W (3.50mm x 3.10mm) 0.102" (2.60mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1054 EAR99 8504.50.8000 10 500 mA Unshielded - 39 µH - 1Ohm - 1 kHz
TCK-044 Traco Power TCK-044 3.8000
RFQ
ECAD 2 0.00000000 Traco Power - Strip Active ±20% -40°C ~ 125°C - 0.228" L x 0.205" W (5.80mm x 5.20mm) 0.205" (5.20mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1055 EAR99 8504.50.8000 10 2 A Unshielded - 3.3 µH - 60mOhm - 1 kHz
TCK-147 Traco Power TCK-147 3.1600
RFQ
ECAD 144 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.138" L x 0.122" W (3.50mm x 3.10mm) 0.102" (2.60mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.50.8000 10 600 mA Unshielded - 15 µH - 600mOhm - 1 kHz
TCK-141 Traco Power TCK-141 6.6900
RFQ
ECAD 1 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 105°C - 0.157" L x 0.157" W (4.00mm x 4.00mm) 0.083" (2.10mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1052 EAR99 8504.50.8000 10 3.5 A Unshielded - 5.6 µH - 90mOhm - 100 kHz
TCK-150 Traco Power TCK-150 4.7500
RFQ
ECAD 80 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.209" L x 0.197" W (5.30mm x 5.00mm) 0.126" (3.20mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.50.8000 10 590 mA Unshielded - 68 µH - 636mOhm -
TCK-130 Traco Power TCK-130 3.2400
RFQ
ECAD 1 0.00000000 Traco Power - Bag Active ±15% -40°C ~ 125°C - 0.138" L x 0.118" W (3.50mm x 3.00mm) 0.106" (2.70mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1046 EAR99 8504.50.8000 10 580 mA Unshielded - 22 µH - 55mOhm - 100 kHz
TCK-112 Traco Power TCK-112 7.4500
RFQ
ECAD 37 0.00000000 Traco Power - Bag Active ±20% -40°C ~ 125°C - 0.256" L x 0.256" W (6.50mm x 6.50mm) 0.157" (4.00mm) Surface Mount Nonstandard - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1034 EAR99 8504.50.8000 10 4 A Unshielded - 12 µH - 53mOhm - 100 kHz
TCK-182 Traco Power TCK-182 2.2620
RFQ
ECAD 9357 0.00000000 Traco Power - Bulk Active ±20% -40°C ~ 125°C - 0.193" L x 0.193" W (4.90mm x 4.90mm) 0.165" (4.19mm) Surface Mount Nonstandard Wirewound - - - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-TCK-182 EAR99 8504.50.8000 10 800 mA Unshielded - 100 µH - 589mOhm Max - 100 kHz
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse