Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Mounting Type | Features | Base Product Number | Color | Termination | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Contact Finish | Contact Material | Gender | Length - Overall | Wire Gauge | Terminal Type | Insulation | Insulation Diameter | Tab Width | Tab Thickness | Tab Length |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DNFR14206FIB-KD | 0.7200 | 1 | 0.00000000 | Panduit Corp | Pan-Term® | Tape & Reel (TR) | Active | Free Hanging (In-Line), Right Angle | Butted Seam | DNFR14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 1,500 | Tin | Brass | Female | - | 14-16 AWG | Angled - 90°, Flag | Fully Insulated | 0.180" (4.57mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.020" (0.51mm) | - | ||||
DNFR14-206FIB-L | 1.3951 | 4860 | 0.00000000 | Panduit Corp | Pan-Term® | Bulk | Active | Free Hanging (In-Line), Right Angle | Butted Seam | DNFR14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 50 | Tin | Brass | Female | - | 14-16 AWG | Angled - 90°, Flag | Fully Insulated | 0.178" (4.52mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.020" (0.51mm) | - | ||||
DNFR18205FIB-KD | 0.7000 | 4 | 0.00000000 | Panduit Corp | Pan-Term® | Tape & Reel (TR) | Active | Free Hanging (In-Line), Right Angle | Butted Seam | DNFR18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 1,500 | Tin | Brass | Female | - | 18-22 AWG | Angled - 90°, Flag | Fully Insulated | 0.180" (4.57mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.032" (0.81mm) | - | ||||
DNFR18206FIB-KD | 0.7000 | 3 | 0.00000000 | Panduit Corp | Pan-Term® | Tape & Reel (TR) | Active | Free Hanging (In-Line), Right Angle | Butted Seam | DNFR18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 1,500 | Tin | Brass | Female | - | 18-22 AWG | Angled - 90°, Flag | Fully Insulated | 0.180" (4.57mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.020" (0.51mm) | - | ||||
DNFR18-250B-L | 1.4900 | 900 | 0.00000000 | Panduit Corp | Pan-Term® | Bulk | Active | Free Hanging (In-Line), Right Angle | Butted Seam | DNFR18 | Red | Crimp | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 50 | Tin | Brass | Female | - | 18-22 AWG | Angled - 90°, Flag | Fully Insulated | 0.130" (3.30mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.032" (0.81mm) | - | ||||
DNG14-250FL-X | - | 2846 | 0.00000000 | Panduit Corp | Disco-Lok™ | Bulk | Obsolete | Free Hanging (In-Line) | Serrated Termination | Blue | Crimp | - | Not Applicable | 07498380698 | EAR99 | 8536.90.4000 | 10 | - | - | Female | 0.250" (6.35mm) | 14-16 AWG | Standard | Fully Insulated | 0.150" (3.81mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||||
DNG18-188FB-3K | - | 4567 | 0.00000000 | Panduit Corp | ReelSmart™ Supra-Grip™ | Tape & Reel (TR) | Obsolete | Free Hanging (In-Line) | Butted Seam | DNG18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.890" (22.61mm) | 18-22 AWG | Standard | Fully Insulated | 0.090" ~ 0.126" (2.29mm ~ 3.20mm) | 0.187" (4.75mm) | 0.020" (0.51mm) | - | ||||
DNG18-250FL-X | - | 5086 | 0.00000000 | Panduit Corp | Disco-Lok™ | Bulk | Obsolete | Free Hanging (In-Line) | Serrated Termination | Red | Crimp | - | Not Applicable | 07498380723 | EAR99 | 8536.90.4000 | 10 | - | - | Female | 0.250" (6.35mm) | 18-22 AWG | Standard | Fully Insulated | 0.126" (3.20mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||||
DPF10-250FIB-2K | 0.7200 | 1 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam | DPF10 | Yellow | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 2,000 | Tin | Brass | Female | 0.960" (24.38mm) | 10-12 AWG | Standard | Fully Insulated | 0.110" ~ 0.220" (2.79mm ~ 5.59mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DPF14-250FIM-2K | 0.7800 | 6229 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | - | DPF14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 2,000 | Nickel | Brass | Male | 0.900" (22.86mm) | 14-16 AWG | Standard | Fully Insulated | 0.090" ~ 0.156" (2.29mm ~ 3.96mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DPF14-250FIMB-K | 0.6811 | 6161 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam | DPF14 | Blue | Crimp | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | 07498320330 | EAR99 | 8536.90.4000 | 1,000 | Nickel | Brass | Male | 0.920" (23.37mm) | 14-16 AWG | Standard | Fully Insulated | 0.090" ~ 0.156" (2.29mm ~ 3.96mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | |||
DPF14-250FIMB-Q | - | 1077 | 0.00000000 | Panduit Corp | DiscoGrip™ | Bulk | Obsolete | Free Hanging (In-Line) | Butted Seam | Blue | Crimp | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 25 | - | - | Male | 0.920" (23.37mm) | 14-16 AWG | Standard | Fully Insulated | 0.156" (3.96mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | |||||
DPF18-205FIB-3K | - | 5344 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Obsolete | Free Hanging (In-Line) | Butted Seam | DPF18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.780" (19.81mm) | 18-22 AWG | Standard | Fully Insulated | 0.060" ~ 0.136" (1.52mm ~ 3.45mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.032" (0.81mm) | - | ||||
DPF18205FIBR-3K | - | 6303 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Obsolete | Free Hanging (In-Line) | Butted Seam | Red | Crimp | - | ROHS3 Compliant | Not Applicable | 07498308931 | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.780" (19.81mm) | 18-22 AWG | Standard | Fully Insulated | 0.060" ~ 0.106" (1.52mm ~ 2.69mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.032" (0.81mm) | - | |||||
DPF18-206FIB-3K | 0.5300 | 17 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam | DPF18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.780" (19.81mm) | 18-22 AWG | Standard | Fully Insulated | 0.060" ~ 0.136" (1.52mm ~ 3.45mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.020" (0.51mm) | - | ||||
DPF18206FIBR-3K | - | 9739 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Obsolete | Free Hanging (In-Line) | Butted Seam | Red | Crimp | - | ROHS3 Compliant | Not Applicable | 07498308932 | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.780" (19.81mm) | 18-22 AWG | Standard | Fully Insulated | 0.060" ~ 0.106" (1.52mm ~ 2.69mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.020" (0.51mm) | - | |||||
DPF18-250FIB-3K | 0.5100 | 3 | 0.00000000 | Panduit Corp | DiscoGrip™, ReelSmart™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam | DPF18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.840" (21.34mm) | 18-22 AWG | Standard | Fully Insulated | 0.060" ~ 0.136" (1.52mm ~ 3.45mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DPF18-250FIBR-C | - | 3361 | 0.00000000 | Panduit Corp | DiscoGrip™ | Bulk | Obsolete | Free Hanging (In-Line) | Butted Seam | Red | Crimp | download | ROHS3 Compliant | Not Applicable | 07498308936 | EAR99 | 8536.90.4000 | 100 | Tin | Brass | Female | 0.840" (21.34mm) | 18-22 AWG | Standard | Fully Insulated | 0.060" ~ 0.106" (1.52mm ~ 2.69mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | |||||
DPFR18205FIB-KD | - | 5240 | 0.00000000 | Panduit Corp | Pan-Term® | Tape & Reel (TR) | Obsolete | Free Hanging (In-Line), Right Angle | Butted Seam | DPFR18205 | Red | Crimp | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 1,500 | Tin | Brass | Female | - | 18-22 AWG | Angled - 90°, Flag | Fully Insulated | 0.180" (4.57mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.032" (0.81mm) | - | ||||
DV10-250C-2K | 0.6600 | 29 | 0.00000000 | Panduit Corp | Pan-Term® | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Serrated Termination | DV10 | Yellow | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 2,000 | Tin | Brass | Female | 0.950" (24.13mm) | 10-12 AWG | Standard | Non-Mating End Insulated | 0.230" (5.84mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DV10-250C-D | - | 7547 | 0.00000000 | Panduit Corp | Pan-Term® | Bulk | Obsolete | Free Hanging (In-Line) | - | Yellow | Crimp | download | ROHS3 Compliant | Not Applicable | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 1.040" (26.42mm) | 10-12 AWG | Standard | Non-Mating End Insulated | 0.229" (5.82mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||||
DV14-187B-3K | 0.4400 | 5 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.770" (19.56mm) | 14-16 AWG | Standard | Non-Mating End Insulated | 0.170" (4.32mm) | 0.187" (4.75mm) | 0.032" (0.81mm) | - | ||||
DV14-188B-3K | 0.4400 | 5 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.770" (19.56mm) | 14-16 AWG | Standard | Non-Mating End Insulated | 0.170" (4.32mm) | 0.187" (4.75mm) | 0.020" (0.51mm) | - | ||||
DV14-250B-3K | 0.4100 | 10 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.830" (21.08mm) | 14-16 AWG | Standard | Non-Mating End Insulated | 0.170" (4.32mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DV14-250B-E | 1.3600 | 14 | 0.00000000 | Panduit Corp | Pan-Term® | Bulk | Obsolete | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV14 | Blue | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 20 | Tin | Brass | Female | 0.810" (20.57mm) | 14-16 AWG | Standard | Non-Mating End Insulated | 0.170" (4.32mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DV14-250P-E | - | 2403 | 0.00000000 | Panduit Corp | Pan-Term® | Bulk | Obsolete | Free Hanging (In-Line) | - | Blue | Crimp | - | ROHS3 Compliant | Not Applicable | EAR99 | 8536.90.4000 | 20 | Tin | Brass | Female and Male | 0.880" (22.35mm) | 14-16 AWG | Stacked | Non-Mating End Insulated | 0.160" (4.06mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||||
DV18-188B-3K | 0.4400 | 13 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.770" (19.56mm) | 18-22 AWG | Standard | Non-Mating End Insulated | 0.150" (3.81mm) | 0.187" (4.75mm) | 0.020" (0.51mm) | - | ||||
DV18-205B-3K | 0.4200 | 2 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.770" (19.56mm) | 18-22 AWG | Standard | Non-Mating End Insulated | 0.150" (3.81mm) | 0.187" (4.75mm), 0.205" (5.21mm) | 0.032" (0.81mm) | - | ||||
DV18-250B-3K | 0.4100 | 7 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Active | Free Hanging (In-Line) | Butted Seam, Serrated Termination | DV18 | Red | Crimp | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.90.4000 | 3,000 | Tin | Brass | Female | 0.830" (21.08mm) | 18-22 AWG | Standard | Non-Mating End Insulated | 0.150" (3.81mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - | ||||
DV18-250MB-3K | - | 4569 | 0.00000000 | Panduit Corp | Disco™ | Tape & Reel (TR) | Obsolete | Free Hanging (In-Line) | Butted Seam | Red | Crimp | download | Not Applicable | 07498382024 | EAR99 | 8536.90.4000 | 3,000 | - | - | Male | 0.900" (22.86mm) | 18-22 AWG | Standard | Non-Mating End Insulated | 0.155" (3.94mm) | 0.250" (6.35mm) | 0.032" (0.81mm) | - |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse