Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Mounting Type | Type | Features | Base Product Number | Includes | Color | Termination | Ingress Protection | Note | DataSheet | RoHS Status | Other Names | ECCN | HTSUS | Standard Package | Connector Type | Current Rating (Amps) | Orientation | Shielding | Material Flammability Rating | Contact Type | Number of Positions | Fastening Type | Contact Shape | Contact Finish - Mating | Voltage Rating | Mounting Feature | Shell Size - Insert | Shell Size, MIL | Primary Material | Shell Material | Shell Finish | Insert Material | Housing Color | Contact Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MS27505E25B61SB-LC | 1.0000 | 2748 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series I | Box | Active | -65°C ~ 175°C | Panel Mount | For Female Sockets | - | MS27505E25B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27505E25B61SB-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | B | Shielded | - | Crimp | 61 | Bayonet Lock | Flange | 25-61 | - | Aluminum | Cadmium | Olive Drab | 20 | ||||||||||||
MS3450W18-9S-LC | 83.6100 | 47 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line); Panel Mount | For Female Sockets | - | MS3450W18 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3450W18-9S-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 7 | Threaded | Flange | 18-9 | - | Aluminum | Cadmium | Olive Drab | 12 (2), 16 (5) | ||||||||||||
MS27497T18F28PC | 1.0000 | 1594 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 200°C | Panel Mount | - | MS27497T18F | Silver | Crimp | - | download | ROHS3 Compliant | 2403-MS27497T18F28PC | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | 7.5A, 13A | C | Shielded | - | 28 | Bayonet Lock | Gold | - | Flange | 18-28 | - | Metal | Aluminum | Nickel | |||||||||||
MS27505E11B5A | 29.6500 | 4 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series I | Box | Active | -65°C ~ 175°C | Panel Mount | For Male Pins | - | MS27505E11B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27505E11B5A | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | Crimp | 5 | Bayonet Lock | Flange | - | Metal | Aluminum | Olive Drab Cadmium | Olive Drab | ||||||||||||||
MS27496E25B4BA | 1.0000 | 2272 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series I | Box | Active | -65°C ~ 175°C | Panel Mount | For Female Sockets | - | MS27496E25B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27496E25B4BA | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | A | Shielded | Crimp | 56 | Bayonet Lock | Flange | 25-4 | - | Metal | Aluminum | Olive Drab Cadmium | Olive Drab | |||||||||||||
MS3450LS16-11SY | 1.0000 | 4532 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 200°C | Panel Mount | - | MS3450LS1 | - | Crimp | IP67 - Dust Tight, Waterproof | download | ROHS3 Compliant | 2403-MS3450LS16-11SY | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | 23A | Y | Shielded | - | 2 | Threaded | Gold | - | Flange | 16-11 | - | Metal | Stainless Steel | Passivated | |||||||||||
MS27474T12F4S-LC | 1.0000 | 1248 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 200°C | Panel Mount | For Female Sockets | - | MS27474T12F | - | Contacts Not Included | download | ROHS3 Compliant | 2403-MS27474T12F4S-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 4 | Bayonet Lock | Bulkhead - Rear Side Nut | 12-4 | - | Aluminum | Nickel | Silver | 16 | ||||||||||||
MS27508E16B6S-LC | 1.0000 | 2154 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 175°C | Panel Mount | For Female Sockets | - | MS27508E16B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27508E16B6S-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 6 | Bayonet Lock | Flange | 16-6 | - | Aluminum | Cadmium | Olive Drab | 12 | ||||||||||||
MS27474T10B99SA-LC | 1.0000 | 7165 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 175°C | Panel Mount | For Female Sockets | - | MS27474T10B | - | Environment Resistant | Contacts Not Included | download | RoHS non-compliant | 2403-MS27474T10B99SA-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | A | Unshielded | - | Crimp | 7 | Bayonet Lock | Circular | Bulkhead - Front Side Nut | 10-99 | - | Aluminum Alloy | Cadmium | Thermoplastic | Olive | 20 | |||||||||
MS27499E10F98P-LC | 45.8500 | 55 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 200°C | Panel Mount | For Male Pins | - | MS27499E10F | - | Contacts Not Included | download | ROHS3 Compliant | 2403-MS27499E10F98P-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 6 | Bayonet Lock | Flange | 10-98 | - | Aluminum | Nickel | Silver | 20 | ||||||||||||
MS27484T24F61S-LC | 96.4000 | 1 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | - | MS27484T24F | - | Contacts Not Included | download | ROHS3 Compliant | 2403-MS27484T24F61S-LC | EAR99 | 8536.69.4020 | 1 | Plug Housing | N (Normal) | Shielded | - | Crimp | 61 | Bayonet Lock | - | 24-61 | - | Aluminum | Nickel | Silver | 20 | ||||||||||||
MS3450KT20-17SY-LC | 1.0000 | 6461 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line); Panel Mount | For Female Sockets | - | MS3450KT2 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3450KT20-17SY-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | Y | Shielded | - | Crimp | 6 | Threaded | Flange | 20-17 | - | Steel | Cadmium | - | 12 (5), 16 (1) | ||||||||||||
MS3451W20-8SY-LC | 1.0000 | 4814 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line) | For Female Sockets | - | MS3451W20 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3451W20-8SY-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | Y | Shielded | - | Crimp | 6 | Threaded | - | 20-8 | - | Aluminum | Cadmium | Olive Drab | 8 (2), 16 (4) | ||||||||||||
MS27508E16F35A | 1.0000 | 5633 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II, JT | Box | Active | -65°C ~ 200°C | Panel Mount | For Male Pins | - | MS27508E16F | - | Environment Resistant | Contacts Not Included | download | ROHS3 Compliant | 2403-MS27508E16F35A | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Unshielded | - | Crimp | 55 | Bayonet Lock | Circular | Flange | 16-35 | - | Aluminum Alloy | Electroless Nickel | - | Silver | 22D | |||||||||
MS3450W20-14SX-LC | 1.0000 | 1671 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line); Panel Mount | For Female Sockets | - | MS3450W20 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3450W20-14SX-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | X | Shielded | - | Crimp | 5 | Threaded | Flange | 20-14 | - | Aluminum | Cadmium | Olive Drab | 8 (2), 12 (3) | ||||||||||||
MS3451W10SL-3P-LC | 1.0000 | 5593 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line) | For Male Pins | - | MS3451W10 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3451W10SL-3P-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 3 | Threaded | - | 10SL-3 | - | Aluminum | Cadmium | Olive Drab | 16 | ||||||||||||
MS27505E25B61S-LC | 1.0000 | 5289 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series I | Box | Active | -65°C ~ 175°C | Panel Mount | For Female Sockets | - | MS27505E25B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27505E25B61S-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 61 | Bayonet Lock | Flange | 25-61 | - | Aluminum | Cadmium | Olive Drab | 20 | ||||||||||||
MS3450LS16-10PY-LC | 1.0000 | 7779 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 200°C | Free Hanging (In-Line); Panel Mount | For Male Pins | - | MS3450LS1 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | ROHS3 Compliant | 2403-MS3450LS16-10PY-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | Y | Shielded | - | Crimp | 3 | Threaded | Flange | 16-10 | - | Stainless Steel | Passivated | - | 12 | ||||||||||||
MS3450W18-8SZ-LC | 1.0000 | 6581 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line); Panel Mount | For Female Sockets | - | MS3450W18 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3450W18-8SZ-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | Z | Shielded | - | Crimp | 8 | Threaded | Flange | 18-8 | - | Aluminum | Cadmium | Olive Drab | 12 (1), 16 (7) | ||||||||||||
MS3450KT18-9SZ | 1.0000 | 6081 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Panel Mount | - | MS3450KT1 | - | Crimp | IP67 - Dust Tight, Waterproof | download | RoHS non-compliant | 2403-MS3450KT18-9SZ | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | 13A, 23A | Z | Shielded | - | 7 | Threaded | Gold | - | Flange | 18-9 | - | Metal | Carbon Steel | Cadmium | |||||||||||
MS27508E24F35AA | 1.0000 | 4122 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II, JT | Box | Active | -65°C ~ 200°C | Panel Mount | For Male Pins | - | MS27508E24F | - | Environment Resistant | Contacts Not Included | download | ROHS3 Compliant | 2403-MS27508E24F35AA | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | A | Unshielded | - | Crimp | 128 | Bayonet Lock | Circular | Flange | 24-35 | - | Aluminum Alloy | Electroless Nickel | - | Silver | 22D | |||||||||
MS3450L18-12PZ | 1.0000 | 6068 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 200°C | Panel Mount | - | MS3450L18 | - | Crimp | IP67 - Dust Tight, Waterproof | download | ROHS3 Compliant | 2403-MS3450L18-12PZ | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | 13A | Z | Shielded | - | 6 | Threaded | Gold | - | Flange | 18-12 | - | Metal | Aluminum | Electroless Nickel | |||||||||||
MS3450LS14S-7S-LC | 110.8100 | 4 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 200°C | Free Hanging (In-Line); Panel Mount | For Female Sockets | - | MS3450LS1 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | ROHS3 Compliant | 2403-MS3450LS14S-7S-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 3 | Threaded | Flange | 14S-7 | - | Stainless Steel | Passivated | - | 16 | ||||||||||||
MS3452L20-29PZ | 95.1300 | 33 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 200°C | Panel Mount | - | MS3452L20 | - | Crimp | IP67 - Dust Tight, Waterproof | download | ROHS3 Compliant | 2403-MS3452L20-29PZ | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | 13A | Z | Shielded | - | 17 | Threaded | Gold | - | Flange | 20-29 | - | Metal | Aluminum | Electroless Nickel | |||||||||||
MS27508E10B35A | 50.8500 | 32 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II, JT | Box | Active | -65°C ~ 175°C | Panel Mount | For Male Pins | - | MS27508E10B | - | Environment Resistant | Contacts Not Included | download | RoHS non-compliant | 2403-MS27508E10B35A | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Unshielded | - | Crimp | 13 | Bayonet Lock | Circular | Flange | 10-35 | - | Aluminum Alloy | Cadmium over Nickel | - | Olive Drab | 22D | |||||||||
MS27508E14B18AA | 1.0000 | 6502 | 0.00000000 | Conesys | MIL-DTL-38999 Series II | Box | Active | -65°C ~ 175°C | Panel Mount | For Male Pins | - | MS27508E14B | - | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27508E14B18AA | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | A | Unshielded | - | Crimp | 18 | Bayonet Lock | Circular | Flange | 14-18 | - | Aluminum | Cadmium over Nickel | - | Olive Drab | 20 | |||||||||
MS3450LS24-22PW | 1.0000 | 9162 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 200°C | Panel Mount | - | MS3450LS2 | - | Crimp | IP67 - Dust Tight, Waterproof | download | ROHS3 Compliant | 2403-MS3450LS24-22PW | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | 46A | W | Shielded | - | 4 | Threaded | Gold | - | Flange | 24-22 | - | Metal | Stainless Steel | Passivated | |||||||||||
MS27497T12B3S-LC | 1.0000 | 4358 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 175°C | Panel Mount | For Female Sockets | - | MS27497T12B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27497T12B3S-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 3 | Bayonet Lock | Flange | 12-3 | - | Aluminum | Cadmium | Olive Drab | 16 | ||||||||||||
MS27497T12B4P-LC | 1.0000 | 9739 | 0.00000000 | Conesys | Military, MIL-DTL-38999 Series II | Box | Active | -65°C ~ 175°C | Panel Mount | For Male Pins | - | MS27497T12B | - | Contacts Not Included | download | RoHS non-compliant | 2403-MS27497T12B4P-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | N (Normal) | Shielded | - | Crimp | 4 | Bayonet Lock | Flange | 12-4 | - | Aluminum | Cadmium | Olive Drab | 16 | ||||||||||||
MS3450KT14S-2SY-LC | 1.0000 | 5931 | 0.00000000 | Conesys | Military, MIL-DTL-5015 Series III | Box | Active | -55°C ~ 175°C | Free Hanging (In-Line); Panel Mount | For Female Sockets | - | MS3450KT1 | IP67 - Dust Tight, Waterproof | Contacts Not Included | download | RoHS non-compliant | 2403-MS3450KT14S-2SY-LC | EAR99 | 8536.69.4020 | 1 | Receptacle Housing | Y | Shielded | - | Crimp | 4 | Threaded | Flange | 14S-2 | - | Steel | Cadmium | - | 16 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse