Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Mounting Type | Type | Features | Base Product Number | Includes | Color | Termination | Ingress Protection | Note | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | Other Names | ECCN | HTSUS | Standard Package | Connector Type | Current Rating (Amps) | Orientation | Shielding | Contact Material | Material Flammability Rating | Contact Type | Number of Positions | Fastening Type | Contact Shape | Contact Finish - Mating | Contact Finish Thickness - Mating | Voltage Rating | Mounting Feature | Shell Size - Insert | Shell Size, MIL | Primary Material | Shell Material | Shell Finish | Cable Opening | Backshell Material, Plating | Insert Material | Housing Color | Contact Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BACC63CC14-3P6H | 1.0000 | ![]() |
1461 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | BACC63CC | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63CC14-3P6H | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 3 (1 + 2 Power) | Bayonet Lock | Circular | Flange | 14-3 | - | Aluminum | Bright Cadmium over Nickel | Epoxy, Glass Filled | Silver | 2 (1), 16 Power (2) | ||||||||||||
![]() |
BACC45FT10-20P6 | 1.0000 | ![]() |
8726 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | BACC45FT | - | Crimp | Environment Sealed | download | RoHS non-compliant | Not Applicable | CBACC45FT10-20P6 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 6 | Unshielded | - | - | 2 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 10-20 | - | Metal | Aluminum | Anodized | 0.420" (10.67mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
CN0966B22G12P10-000 | 1.0000 | ![]() |
2831 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0966 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut, Self Locking | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0966B22G12P10-000 | EAR99 | 8538.90.8180 | 1 | Plug Housing | 10 | Shielded | - | Crimp | 12 (Power) | Threaded | Circular | - | 22-12 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 12 Power | ||||||||||||
![]() |
CN1020A20G28SN-000 | 1.0000 | ![]() |
8095 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN1020 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | Coupling Nut | CN102 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN1020A20G28SN-000 | EAR99 | 8538.90.8180 | 1 | Plug Housing | N (Normal) | Shielded | - | Crimp | 28 (Power) | Bayonet Lock | Circular | - | 20-28 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 12 Power (4), 20 Power (24) | ||||||||||||
![]() |
BACC63BP20D39SN | 1.0000 | ![]() |
7054 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut, Self Locking | BACC63BP | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BP20D39SN | EAR99 | 8536.69.4020 | 1 | Plug, Female Sockets | - | N (Normal) | Shielded | - | - | 39 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 20-39 | - | Metal | Stainless Steel | - | 0.986" (25.04mm) | - | - | ||||||||
![]() |
BACC63CC22-12P6H | 1.0000 | ![]() |
6347 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | BACC63CC | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63CC22-12P6H | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 12 (Power) | Bayonet Lock | Circular | Flange | 22-12 | - | Aluminum | Bright Cadmium over Nickel | Epoxy, Glass Filled | Silver | 12 Power | ||||||||||||
![]() |
CN1020A22G19P6-200 | 1.0000 | ![]() |
6935 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN1020 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | - | CN102 | - | Crimp | Environment Sealed | download | RoHS non-compliant | Not Applicable | CCN1020A22G19P6-200 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 6 | Shielded | - | - | 19 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 22-19 | - | Metal | Aluminum | Cadmium over Nickel | 1.106" (28.09mm) | - | - | ||||||||
![]() |
BACC63BN20-39SNH | 1.0000 | ![]() |
2733 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | Coupling Nut | BACC63BN | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BN20-39SNH | EAR99 | 8538.90.8180 | 1 | Plug Housing | N (Normal) | Unshielded | - | Crimp | 39 (Power) | Bayonet Lock | Circular | - | 20-39 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power (2), 20 Power (37) | ||||||||||||
![]() |
BACC45FT14-7P7H | 1.0000 | ![]() |
9073 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut | BACC45FT | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC45FT14-7P7H | EAR99 | 8538.90.8180 | 1 | Plug Housing | 7 | Unshielded | - | Crimp | 7 (Power) | Bayonet Lock | Circular | - | 14-7 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power | ||||||||||||
![]() |
CN0966B20G25P8Y140 | 296.4900 | ![]() |
13 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0966 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut, Ground, Self Locking | CN096 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CCN0966B20G25P8Y140 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 8 | Shielded | - | - | 25 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 20-25 | - | Metal | Aluminum | Cadmium over Nickel | 0.986" (25.04mm) | - | - | ||||||||
![]() |
BACC63BP24C61P6 | 1.0000 | ![]() |
7242 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut, Self Locking | BACC63BP | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BP24C61P6 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 6 | Shielded | - | - | 61 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 24-61 | - | Metal | Aluminum | Cadmium over Nickel | 1.235" (31.37mm) | - | - | ||||||||
![]() |
BACC45FS12C3S6 | 137.0700 | ![]() |
6 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Cable Clamp, Coupling Nut | BACC45FS | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CBACC45FS12C3S6 | EAR99 | 8536.69.4020 | 1 | Plug, Female Sockets | - | 6 | Unshielded | - | - | 3 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 12-3 | - | Metal | Aluminum | Anodized | 0.580" (14.73mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
C48-16R8Y3P-406 | 1.0000 | ![]() |
5552 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut | C48-16R8 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CC48-16R8Y3P-406 | EAR99 | 8538.90.8180 | 1 | Plug Housing | N (Normal) | Unshielded | - | Crimp | 3 (Power) | Bayonet Lock | Circular | - | 8-3 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 20 Power | ||||||||||||
![]() |
CN1021A24G30S6-040 | 1.0000 | ![]() |
7155 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN1021 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | CN102 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN1021A24G30S6-040 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 6 | Shielded | - | Crimp | 30 (Power) | Bayonet Lock | Circular | Flange | 24-30 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 16 Power | ||||||||||||
![]() |
C48-00R16-10S6-402 | 106.2200 | ![]() |
20 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | C48-00R1 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CC48-00R16-10S6-402 | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | - | 6 | - | - | - | 10 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | Flange | 16-10 | - | Metal | Aluminum | Anodized | - | - | Epoxy, Glass Filled | ||||||||
![]() |
MS24265R14B4P7-LC | 1.0000 | ![]() |
8570 | 0.00000000 | Cinch Connectivity Solutions | Military, MIL-DTL-26500 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | MS24265R14B | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CMS24265R14B4P7-LC | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 7 | Unshielded | - | Crimp | 4 (Power) | Bayonet Lock | Circular | Bulkhead - Front Side Nut | 14-4 | D | Aluminum | Anodized | Epoxy, Glass Filled | Black | 12 Power | ||||||||||||
![]() |
CN0967C12S12S7-000 | 1.0000 | ![]() |
6640 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0967 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0967C12S12S7-000 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 7 | Shielded | - | Crimp | 12 (Power) | Threaded | Circular | Flange | 12-12 | - | Stainless Steel | - | Epoxy, Glass Filled | Silver | 20 Power | ||||||||||||
![]() |
BACC63BV20B25P7H | 1.0000 | ![]() |
2574 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | BACC63BV | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC63BV20B25P7H | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 7 | Shielded | - | Crimp | 25 (Power) | Threaded | Circular | Flange | 20-25 | - | Stainless Steel | - | Epoxy, Glass Filled | Silver | 12 Power (6), 20 Power (19) | ||||||||||||
![]() |
MS24266R10B2S8-LC | 1.0000 | ![]() |
2876 | 0.00000000 | Cinch Connectivity Solutions | Military, MIL-DTL-26500 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | Coupling Nut | MS24266R10B | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CMS24266R10B2S8-LC | EAR99 | 8538.90.8180 | 1 | Plug Housing | 8 | Unshielded | - | Crimp | 2 (Power) | Bayonet Lock | Circular | - | 10-2 | B | Aluminum | Anodized | Epoxy, Glass Filled | Black | 20 Power | ||||||||||||
![]() |
MS24264R14T7S8-LC | 1.0000 | ![]() |
6455 | 0.00000000 | Cinch Connectivity Solutions | Military, MIL-DTL-26500 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Female Sockets | - | MS24264R14T | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CMS24264R14T7S8-LC | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 8 | Unshielded | - | Crimp | 7 (Power) | Threaded | Circular | Flange | 14-7 | D | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power | ||||||||||||
![]() |
C48-06R14-12S7-102 | 1.0000 | ![]() |
2668 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | C48-06R1 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CC48-06R14-12S7-102 | EAR99 | 8536.69.4020 | 1 | Plug, Female Sockets | - | 7 | - | - | - | 12 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 14-12 | - | Metal | Aluminum | Anodized | 0.664" (16.87mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
BACC45FT20-39S10H | 1.0000 | ![]() |
4905 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC45 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | Coupling Nut | BACC45FT | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CBACC45FT20-39S10H | EAR99 | 8538.90.8180 | 1 | Plug Housing | 10 | Unshielded | - | Crimp | 39 (Power) | Bayonet Lock | Circular | - | 20-39 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power (2), 20 Power (37) | ||||||||||||
![]() |
BACC63BP22H39P6H | 1.0000 | ![]() |
9816 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, BACC63 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut, Self Locking | BACC63BP | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | Not Applicable | CBACC63BP22H39P6H | EAR99 | 8538.90.8180 | 1 | Plug Housing | 6 | Shielded | - | Crimp | 39 (Power) | Threaded | Circular | - | 22-39 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power (12), 20 Power (27) | ||||||||||||
![]() |
C48-16R22-19P7-402 | 143.6800 | ![]() |
3 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut | C48-16R2 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CC48-16R22-19P7-402 | EAR99 | 8536.69.4020 | 1 | Plug, Male Pins | - | 7 | - | - | - | 19 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | - | 22-19 | - | Metal | Aluminum | Anodized | 1.152" (29.26mm) | - | Epoxy, Glass Filled | ||||||||
![]() |
CN0966B18G08P6-040 | 1.0000 | ![]() |
1670 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0966 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Male Pins | Coupling Nut, Self Locking | CN096 | - | Environment Sealed | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN0966B18G08P6-040 | EAR99 | 8538.90.8180 | 1 | Plug Housing | 6 | Shielded | - | Crimp | 8 (Power) | Threaded | Circular | - | 18-8 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 12 Power | ||||||||||||
![]() |
CN1021A12G03PN-240 | 1.0000 | ![]() |
8784 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN1021 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | CN102 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CCN1021A12G03PN-240 | EAR99 | 8536.69.4020 | 1 | Receptacle, Male Pins | - | N (Normal) | Shielded | - | - | 3 (Power) | Bayonet Lock | Gold | - | - | Flange | 12-3 | - | Metal | Aluminum | Cadmium over Nickel | 0.547" (13.89mm) | - | - | ||||||||
![]() |
C48-10R20Y28S-402 | 1.0000 | ![]() |
4533 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | - | Panel Mount | - | C48-10R2 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CC48-10R20Y28S-402 | EAR99 | 8536.69.4020 | 1 | Receptacle, Female Sockets | - | N (Normal) | - | - | - | 28 (Power) | Bayonet Lock | Gold | 50.0µin (1.27µm) | - | Flange | 20-28 | - | Metal | Aluminum | Anodized | - | - | Epoxy, Glass Filled | ||||||||
![]() |
CN0966B22G12S7-200 | 281.5400 | ![]() |
1 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN0966 | Bulk | Active | -55°C ~ 200°C | - | Free Hanging (In-Line) | Coupling Nut, Ground, Self Locking | CN096 | - | Crimp | Environment Sealed | download | RoHS non-compliant | 1 (Unlimited) | CCN0966B22G12S7-200 | EAR99 | 8536.69.4020 | 1 | Plug, Female Sockets | - | 7 | Shielded | - | - | 12 (Power) | Threaded | Gold | 50.0µin (1.27µm) | - | - | 22-12 | - | Metal | Aluminum | Cadmium over Nickel | 1.106" (28.09mm) | - | - | ||||||||
![]() |
CN1020A24G57S8Y040 | 270.0800 | ![]() |
14 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, CN1020 | Bulk | Active | -55°C ~ 200°C | Free Hanging (In-Line) | For Female Sockets | Coupling Nut | CN102 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CCN1020A24G57S8Y040 | EAR99 | 8538.90.8180 | 1 | Plug Housing | 8 | Shielded | - | Crimp | 57 (Power) | Bayonet Lock | Circular | - | 24-57 | - | Aluminum | Cadmium over Nickel | Epoxy, Glass Filled | Silver | 12 Power (2), 20 Power (55) | ||||||||||||
![]() |
C48-00R22-19P9-406 | 1.0000 | ![]() |
4070 | 0.00000000 | Cinch Connectivity Solutions | MIL-DTL-26500, C48 | Bulk | Active | -55°C ~ 200°C | Panel Mount | For Male Pins | - | C48-00R2 | - | IP66 - Dust Tight, Water Resistant | Contacts Not Included | download | RoHS non-compliant | 1 (Unlimited) | CC48-00R22-19P9-406 | EAR99 | 8538.90.8180 | 1 | Receptacle Housing | 9 | Unshielded | - | Crimp | 19 (Power) | Threaded | Circular | Flange | 22-19 | - | Aluminum | Anodized | Epoxy, Glass Filled | Black | 16 Power |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse