SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Features Base Product Number Approval Agency Termination Ingress Protection DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Filter Type Connector Type Current Rating (Amps) Material Flammability Rating Number of Positions Voltage Rating Panel Cutout Dimensions Connector Style Panel Thickness Current Rating - Appliance Inlet Voltage Rating - Appliance Inlet Current Rating - Filter Switch Features Current Rating - Circuit Breaker Accomodates a Fuse Fuse Holder, Drawer
DC12.1232.101 SCHURTER Inc. DC12.1232.101 35.7200
RFQ
ECAD 20 0.00000000 SCHURTER Inc. DC12 - Active Panel Mount, Snap-In Shielded, V-Lock Notch DC12.1232 - Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 10 Receptacle, Male Pins - Module - - - - - - 0.039" ~ 0.118" (1.00mm ~ 3.00mm)
DC12.3102.103 SCHURTER Inc. DC12.3102.103 29.8500
RFQ
ECAD 7719 0.00000000 SCHURTER Inc. DC12 Bulk Active Panel Mount, Snap-In Shielded, V-Lock Notch DC12.3102 CQC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 29.40mm x 33.10mm IEC 320-C14 0.039" ~ 0.118" (1.00mm ~ 3.00mm) 10A 250VAC 4A Switch On-Off - No -
DC12.5122.101 SCHURTER Inc. DC12.5122.101 35.7200
RFQ
ECAD 10 0.00000000 SCHURTER Inc. DC12 - Active Panel Mount, Snap-In Shielded, V-Lock Notch DC12.5122 - Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 10 Receptacle, Male Pins - Module - - - - - - 0.039" ~ 0.118" (1.00mm ~ 3.00mm)
DC12.5202.101 SCHURTER Inc. DC12.5202.101 33.9000
RFQ
ECAD 4935 0.00000000 SCHURTER Inc. DC12 Bulk Active Panel Mount, Snap-In Shielded, V-Lock Notch DC12.5202 CQC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 10 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 29.40mm x 33.10mm IEC 320-C14 0.039" ~ 0.118" (1.00mm ~ 3.00mm) 10A 250VAC 10A Switch On-Off - No -
DC12.5232.001 SCHURTER Inc. DC12.5232.001 35.7200
RFQ
ECAD 10 0.00000000 SCHURTER Inc. DC12 - Active Panel Mount, Flange Shielded, V-Lock Notch DC12.5232 - Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 10 Receptacle, Male Pins - Module - - - - - - -
DF11.1477.0010.01 SCHURTER Inc. DF11.1477.0010.01 35.2100
RFQ
ECAD 7744 0.00000000 SCHURTER Inc. DF11 Bulk Active Panel Mount, Flange - DF11.1477 cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected DF11.ABTBH100C0.0010.01 EAR99 8536.30.8000 20 Unfiltered - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 29.00mm x 73.50mm IEC 320-C14 - 10A 250VAC - Circuit Breaker, Switch On-Off 10A No -
EF11.1617.0010.01 SCHURTER Inc. EF11.1617.0010.01 49.8300
RFQ
ECAD 1700 0.00000000 SCHURTER Inc. EF11 Bulk Active Panel Mount, Flange - EF11.1617 cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EF11.A326F160C0.0010.01 EAR99 8536.30.8000 16 Unfiltered - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 32.50mm x 79.50mm IEC 320-C20 - 10A 250VAC - Circuit Breaker, Switch On-Off, Illuminated 16A No -
EF11.2196.0013.01 SCHURTER Inc. EF11.2196.0013.01 39.8100
RFQ
ECAD 5461 0.00000000 SCHURTER Inc. EF11 Bulk Active Panel Mount, Snap-In - EF11.2196 cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EF11.ABDBL200C0.0013.01 EAR99 8536.30.8000 16 Unfiltered - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 32.50mm x 79.50mm IEC 320-C20 0.079" (2.00mm) 10A 250VAC - Circuit Breaker, Switch On-Off 20A No -
EF12.0924.1210.01 SCHURTER Inc. EF12.0924.1210.01 79.9600
RFQ
ECAD 7999 0.00000000 SCHURTER Inc. EF12 Bulk Active Panel Mount, Flange Shielded EF12.0924 cURus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EF12.A324L200C0.1210.01 EAR99 8537.10.9170 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 33.90mm x 81.00mm IEC 320-C20 - 10A 250VAC 20A Circuit Breaker, Switch On-Off, Illuminated 20A No -
EF12.2105.1110.01 SCHURTER Inc. EF12.2105.1110.01 72.1800
RFQ
ECAD 88 0.00000000 SCHURTER Inc. EF12 Bulk Active Panel Mount, Flange Shielded EF12.2105 cURus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8537.10.9170 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 33.90mm x 81.00mm IEC 320-C20 - 10A 250VAC 20A Circuit Breaker, Switch On-Off 16A No -
GRM4.4322.013.C SCHURTER Inc. GRM4.4322.013.C -
RFQ
ECAD 2817 0.00000000 SCHURTER Inc. GRM4 Bulk Obsolete Panel Mount, Snap-In Cover, Shielded, Voltage Selector cULus, VDE Quick Connect - 0.189" (4.8mm) IP40 download ROHS3 Compliant Vendor Undefined REACH Unaffected EAR99 8536.30.8000 120 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 34.20mm x 40.90mm IEC 320-C14 0.059" (1.50mm) 10A 250VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
GSP1.9101.1 SCHURTER Inc. GSP1.9101.1 2.4600
RFQ
ECAD 262 0.00000000 SCHURTER Inc. GSP1 Bulk Active Panel Mount, Flange; Through Hole, Right Angle - GSP1.9101 CCC, cURus, ENEC Solder IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 50 Unfiltered - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 30.30mm x 22.50mm IEC 320-C14 0.118" (3.00mm) 10A 250VAC - - - No -
KMF1.1123.1101 SCHURTER Inc. KMF1.1123.1101 24.1400
RFQ
ECAD 5564 0.00000000 SCHURTER Inc. KMF - Active Panel Mount, Snap-In Shielded KMF1.1123 - Quick Connect - 0.189" (4.8mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 20 - - - - - - - 0.039" ~ 0.098" (1.00mm ~ 2.50mm)
KP01.1112.81 SCHURTER Inc. KP01.1112.81 29.5100
RFQ
ECAD 4253 0.00000000 SCHURTER Inc. KP Bulk Active - Terminating Cover KP01.1112 CCC, cURus, VDE - IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 50 Unfiltered - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Variable Size IEC 320-C14 - 10A 250VAC - Switch On-Off - No -
06GEEG3E Delta Electronics 06GEEG3E 6.1100
RFQ
ECAD 11 0.00000000 Delta Electronics GE Bulk Active Panel Mount, Flange - 06GEEG CSA, UL, VDE Quick Connect - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 603-1155 EAR99 8536.30.8000 270 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 28.45mm x 21.60mm IEC 320-C14 - 6A 115/250VAC 6A - - No -
PF0030/63 Bulgin PF0030/63 9.9000
RFQ
ECAD 2 0.00000000 Bulgin PF Bulk Active Panel Mount, Flange - PF0030 CSA, UL Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.4030 200 Unfiltered - Commercial Receptacle, Male Blades - Module UL94 V-0 3 Rectangular - 27.30mm x 31.12mm IEC 320-C14 - 10A 250VAC - - - Yes (Fuse Not Included) Drawer Included, Twin Fused
6182.0033 SCHURTER Inc. 6182.0033 4.8100
RFQ
ECAD 1 0.00000000 SCHURTER Inc. 5001 Bulk Active Panel Mount, Flange; Through Hole, Right Angle - CCC, cCSAus, ENEC Solder IP20 - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 50 Unfiltered - Commercial Receptacle, Female Sockets UL94 V-0 3 Rectangular - 34.40mm x 25.90mm IEC 320-2-2/F 0.126" (3.20mm) 10A 250VAC - - - No -
5120.2003.0 SCHURTER Inc. 5120.2003.0 7.7900
RFQ
ECAD 6301 0.00000000 SCHURTER Inc. 5120 Bulk Active Panel Mount, Snap-In Shielded 5120.2003 CCC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 29.40mm x 21.50mm IEC 320-C14 0.031" ~ 0.079" (0.79mm ~ 2.00mm) 4A 250VAC 4A - - No -
5120.2006.0 SCHURTER Inc. 5120.2006.0 7.7900
RFQ
ECAD 2289 0.00000000 SCHURTER Inc. 5120 Bulk Active Panel Mount, Snap-In Shielded 5120.2006 CCC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1356 EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 29.40mm x 21.50mm IEC 320-C14 0.031" ~ 0.079" (0.79mm ~ 2.00mm) 10A 250VAC 10A - - No -
5120.2203.0 SCHURTER Inc. 5120.2203.0 7.7900
RFQ
ECAD 20 0.00000000 SCHURTER Inc. 5120 Bulk Active Panel Mount, Snap-In Bleed Resistor, Shielded 5120.2203 CCC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1360 EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 29.40mm x 21.50mm IEC 320-C14 0.031" ~ 0.079" (0.79mm ~ 2.00mm) 4A 250VAC 4A - - No -
5120.2303.0 SCHURTER Inc. 5120.2303.0 7.7900
RFQ
ECAD 5747 0.00000000 SCHURTER Inc. 5120 Bulk Active Panel Mount, Snap-In Shielded 5120.2303 CCC, cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1366 EAR99 8536.30.8000 10 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades UL94 V-0 3 Rectangular - 29.40mm x 21.50mm IEC 320-C14 0.031" ~ 0.079" (0.79mm ~ 2.00mm) 4A 250VAC 4A - - No -
5130.0001 SCHURTER Inc. 5130.0001 13.7200
RFQ
ECAD 40 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Flange Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1371 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 - 16A 250VAC 16/20A - - No -
5130.0101 SCHURTER Inc. 5130.0101 14.4100
RFQ
ECAD 176 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Flange Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1373 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 - 16A 250VAC 16/20A - - No -
5130.0200 SCHURTER Inc. 5130.0200 14.8200
RFQ
ECAD 9 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Flange Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1374 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 - 16A 250VAC 16/20A - - No -
5130.0201 SCHURTER Inc. 5130.0201 14.8200
RFQ
ECAD 66 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Flange Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1375 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 - 16A 250VAC - - - No -
5130.1001 SCHURTER Inc. 5130.1001 13.7200
RFQ
ECAD 122 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Flange Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1379 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 36.50mm x 28.50mm IEC 320-C20 - 16A 250VAC 16/20A - - No -
5130.2001 SCHURTER Inc. 5130.2001 13.7200
RFQ
ECAD 6178 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Snap-In Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1387 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 0.031" ~ 0.118" (0.79mm ~ 3.00mm) 16A 250VAC 16/20A - - No -
5130.2100 SCHURTER Inc. 5130.2100 14.4100
RFQ
ECAD 135 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Snap-In Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1388 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 0.031" ~ 0.118" (0.79mm ~ 3.00mm) 16A 250VAC 16/20A - - No -
5130.2101 SCHURTER Inc. 5130.2101 14.4100
RFQ
ECAD 7161 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Snap-In Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 0.031" ~ 0.118" (0.79mm ~ 3.00mm) 16A 250VAC 16/20A - - No -
5130.2300 SCHURTER Inc. 5130.2300 15.5600
RFQ
ECAD 10 0.00000000 SCHURTER Inc. 5130 Bulk Active Panel Mount, Snap-In Shielded cULus, ENEC Quick Connect - 0.250" (6.3mm) IP40 download ROHS3 Compliant Not Applicable REACH Unaffected 486-1392 EAR99 8536.30.8000 20 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades UL94 V-0 3 Rectangular - 35.00mm x 27.00mm IEC 320-C20 0.031" ~ 0.118" (0.79mm ~ 3.00mm) 16A 250VAC - - - No -
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse