SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Features Base Product Number Approval Agency Termination Ingress Protection DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Filter Type Connector Type Material Flammability Rating Number of Positions Panel Cutout Dimensions Connector Style Panel Thickness Current Rating - Appliance Inlet Voltage Rating - Appliance Inlet Current Rating - Filter Switch Features Current Rating - Circuit Breaker Accomodates a Fuse Fuse Holder, Drawer
1-6609956-4 TE Connectivity Corcom Filters 1-6609956-4 16.4338
RFQ
ECAD 1476 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Voltage Selector 6609956 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PE00SS000 EAR99 8536.69.8000 16 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120/250VAC - - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6609921 TE Connectivity Corcom Filters 6609921 29.3531
RFQ
ECAD 7978 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange - CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PECS0DHX0 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
9-6609939-0 TE Connectivity Corcom Filters 9-6609939-0 26.3758
RFQ
ECAD 7497 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded, Voltage Selector 6609939 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
4-6609929-4 TE Connectivity Corcom Filters 4-6609929-4 32.7900
RFQ
ECAD 38 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange - 6609929 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8537.10.9170 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6-6609960-6 TE Connectivity Corcom Filters 6-6609960-6 17.1638
RFQ
ECAD 4949 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609960 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSCS0D000 EAR99 8536.69.8000 16 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
9-6609947-9 TE Connectivity Corcom Filters 9-6609947-9 23.6919
RFQ
ECAD 4592 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609947 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSJ00DS60 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
4-6609106-7 TE Connectivity Corcom Filters 4-6609106-7 23.0659
RFQ
ECAD 5402 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609106 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
9-6609930-0 TE Connectivity Corcom Filters 9-6609930-0 25.5900
RFQ
ECAD 3895 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip 6609930 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PE000SHX0 EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder
3ED1 TE Connectivity Corcom Filters 3ED1 21.0400
RFQ
ECAD 170 0.00000000 TE Connectivity Corcom Filters ED, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount 3E CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable Vendor Undefined EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 3A 120/250VAC 3A - - No -
4-6609960-3 TE Connectivity Corcom Filters 4-6609960-3 22.4325
RFQ
ECAD 4788 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Interconnection Block, Voltage Selector 6609960 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSCSXDBXA EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
3EXM4 TE Connectivity Corcom Filters 3EXM4 73.4200
RFQ
ECAD 13 0.00000000 TE Connectivity Corcom Filters M, Corcom Bulk Active Panel Mount, Flange Voltage Selector CSA, UL, VDE Quick Connect - 0.110" (2.8mm) - download ROHS3 Compliant 1 (Unlimited) Vendor Undefined EAR99 8537.10.9170 4 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 75.44mm x 29.21mm IEC 320-C14 - 3A 120/250VAC 3A - - Yes (Fuse Not Included) Fuse Holder
1-6609942-2 TE Connectivity Corcom Filters 1-6609942-2 23.6947
RFQ
ECAD 4426 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange - 6609942 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable Vendor Undefined EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
1EGG8-1 TE Connectivity Corcom Filters 1EGG8-1 23.1391
RFQ
ECAD 7926 0.00000000 TE Connectivity Corcom Filters GG, Corcom Bulk Active Panel Mount, Flange - CSA, UL, VDE Wire Leads - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8536.30.8000 36 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.96mm x 33.02mm IEC 320-C14 - 1A 120/250VAC 1A - - Yes (Fuse Not Included) Fuse Holder
5-6609929-4 TE Connectivity Corcom Filters 5-6609929-4 38.3600
RFQ
ECAD 21 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded 6609929 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6609131-7 TE Connectivity Corcom Filters 6609131-7 155.2900
RFQ
ECAD 14 0.00000000 TE Connectivity Corcom Filters M, Corcom Bulk Active Panel Mount, Flange - 6609131 CSA, UL, VDE Quick Connect - 0.110" (2.8mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8548.00.0000 4 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 83.06mm x 29.21mm IEC 320-C14 - 3A 120/250VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
10EC1 TE Connectivity Corcom Filters 10EC1 25.3700
RFQ
ECAD 1873 0.00000000 TE Connectivity Corcom Filters EC, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount 10E CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 10A 120/250VAC 10A - - No -
6609008-2 TE Connectivity Corcom Filters 6609008-2 12.2700
RFQ
ECAD 33 0.00000000 TE Connectivity Corcom Filters EJH, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount 6609008 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 3A 120/250VAC 3A - - No -
3IHE1 TE Connectivity Corcom Filters 3IHE1 12.3300
RFQ
ECAD 27 0.00000000 TE Connectivity Corcom Filters IH, Corcom Bulk Active Panel Mount, Flange - CSA, UL, VDE Quick Connect - 0.189" (4.8mm) - download ROHS3 Compliant Not Applicable Vendor Undefined EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - 2 Rectangular - 30.20mm x 23.50mm IEC 320-C18 - 3A 120/250VAC 3A - - No -
2-6609106-0 TE Connectivity Corcom Filters 2-6609106-0 25.0994
RFQ
ECAD 2396 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Shielded 6609106 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
3-6609107-7 TE Connectivity Corcom Filters 3-6609107-7 23.4138
RFQ
ECAD 6229 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Conversion Clip, Voltage Selector 6609107 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder
3-6609942-2 TE Connectivity Corcom Filters 3-6609942-2 22.3765
RFQ
ECAD 4345 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange - 6609942 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
20SRB1-W TE Connectivity Corcom Filters 20SRB1-W 7.3700
RFQ
ECAD 99 0.00000000 TE Connectivity Corcom Filters SRB, Corcom Tray Active Panel Mount, Flange Front or Rear Side Mount 20S CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.4030 24 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C20 - 20A 120/250VAC 20A - - No -
PS0S0DSX0 TE Connectivity Corcom Filters PS0S0DSX0 29.4500
RFQ
ECAD 615 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - PS0S0D CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant 1 (Unlimited) Vendor Undefined EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6609017-5 TE Connectivity Corcom Filters 6609017-5 24.0700
RFQ
ECAD 37 0.00000000 TE Connectivity Corcom Filters EC, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount 6609017 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8548.00.0000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 3A 120/250VAC 3A - - No -
6609117-3 TE Connectivity Corcom Filters 6609117-3 19.5800
RFQ
ECAD 8 0.00000000 TE Connectivity Corcom Filters GG, Corcom Bulk Active Panel Mount, Snap-In - 6609117 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 36 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.96mm x 33.02mm IEC 320-C14 - 3A 120/250VAC 3A - - Yes (Fuse Not Included) Fuse Holder
3-6609941-4 TE Connectivity Corcom Filters 3-6609941-4 27.7992
RFQ
ECAD 9347 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded, Voltage Selector 6609941 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
9-6609928-7 TE Connectivity Corcom Filters 9-6609928-7 28.7150
RFQ
ECAD 7020 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Shielded, Voltage Selector 6609928 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
1-6609103-8 TE Connectivity Corcom Filters 1-6609103-8 50.5500
RFQ
ECAD 16 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded 6609103 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8537.10.9170 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
2-6609962-5 TE Connectivity Corcom Filters 2-6609962-5 20.4850
RFQ
ECAD 2103 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Interconnection Block, Voltage Selector 6609962 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSLSXDBX0 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6609117-6 TE Connectivity Corcom Filters 6609117-6 21.2600
RFQ
ECAD 155 0.00000000 TE Connectivity Corcom Filters GG, Corcom Bulk Active Panel Mount, Snap-In - 6609117 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 36 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 31.50mm x 32.77mm IEC 320-C14 - 6A 120/250VAC 6A - - Yes (Fuse Not Included) Fuse Holder
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse