SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Approval Agency DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal)
1180-02-8A E-T-A 1180-02-8A 43.6300
RFQ
ECAD 7360 0.00000000 E-T-A 1180 Bulk Active Holder CSA C22.2 No 235, CQC, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 8A 250 V 72 V Push-Push 1 None -
ESX10-TC-101-DC48V-3A E-T-A ESX10-TC-101-DC48V-3A 91.9900
RFQ
ECAD 2262 0.00000000 E-T-A ESX10-T Bulk Active DIN Rail CSA C22.2 No 14, UL2367, UL508, UL Class I Div 2 - Not Applicable 302-ESX10-TC-101-DC48V-3A 1 Solid State 3A 48 V Slide Switch 1 None -
583-G111-J3M1-C4S1U-20A E-T-A 583-G111-J3M1-C4S1U-20A 781.6500
RFQ
ECAD 4138 0.00000000 E-T-A 583 Bulk Active Panel Mount - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 20A 200 V 28 V Push-Pull Plunger 3 None -
1180-01-1.5A E-T-A 1180-01-1.5A 21.8000
RFQ
ECAD 9289 0.00000000 E-T-A 1180 Bulk Active Holder CSA C22.2 No 235, CQC, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 1.5A 250 V 72 V Push-Push 1 None -
ESX10-103-DC24V-2A-E E-T-A ESX10-103-DC24V-2A-E 91.9900
RFQ
ECAD 8622 0.00000000 E-T-A ESX10 Bulk Active Holder CSA C22.2 No 14, UL508 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 1 Solid State 2A 32 V Slide Switch 1 Green, Orange, Red -
3120-F623-P7T1-W19LG3-0.5A E-T-A 3120-F623-P7T1-W19LG3-0.5A -
RFQ
ECAD 6508 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 500mA 250 V 50 V Rocker 2 Green 90V
3120-F321-P7T1-W14DR3-20A E-T-A 3120-F321-P7T1-W14DR3-20A -
RFQ
ECAD 6048 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 20A 250 V 50 V Rocker 2 Red 90V
3120-F321-P7T1-W14FR3-3A E-T-A 3120-F321-P7T1-W14FR3-3A -
RFQ
ECAD 7722 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 3A 250 V 50 V Rocker 2 Red 90V
X1180-01-ST201-5A-B E-T-A X1180-01-ST201-5A-B 23.9200
RFQ
ECAD 9637 0.00000000 E-T-A X1180 Bulk Active Holder CSA C22.2 No 235, UL1059, UL1077, UL786E, VDE - Not Applicable 302-X1180-01-ST201-5A-B 1 Thermal 5A 250 V 72 V Pushbutton 1 None -
3120-N311-P7T1-W14XR3-3A E-T-A 3120-N311-P7T1-W14XR3-3A 27.3920
RFQ
ECAD 5104 0.00000000 E-T-A 3120-N Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected 302-3120-N311-P7T1-W14XR3-3A EAR99 8536.20.0020 10 Thermal 3A 415 V 50 V Rocker 1 Red 115V
2210-S231-P1T1-Z241-4A E-T-A 2210-S231-P1T1-Z241-4A 112.6100
RFQ
ECAD 5515 0.00000000 E-T-A 2210-S2 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 4A 480 V 65 V Lever 3 None -
9510-G213-W4F1-Z0C2B1-1/2A E-T-A 9510-G213-W4F1-Z0C2B1-1/2A 125.0830
RFQ
ECAD 5102 0.00000000 E-T-A 9510 Bulk Active Panel Mount - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic 2A 5 V 28 V Push-Pull Plunger 1 None -
8330-FG10-PWBS-YAAB004-903802-2.5A E-T-A 8330-FG10-PWBS-YAAB004-903802-2.5A -
RFQ
ECAD 5870 0.00000000 E-T-A 8330 Bulk Obsolete Panel Mount - Not Applicable REACH Unaffected 302-1593 EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 2.5A 250 V 80 V Rocker 1 Red 185V
2216-S110-P1F1-S111-A-8S0058-10A E-T-A 2216-S110-P1F1-S111-A-8S0058-10A 100.8400
RFQ
ECAD 6781 0.00000000 E-T-A 2216-S Bulk Active Holder CSA C22.2 No 235, IEC 60934, GB 17701, UL1077 - Not Applicable REACH Unaffected 302-1584 EAR99 8536.20.0020 1 Thermal Magnetic 10A 240 V 50 V Slide Switch 1 None -
1658-G21-09-P10-7A E-T-A 1658-G21-09-P10-7A 3.8289
RFQ
ECAD 8260 0.00000000 E-T-A 1658 Bulk Active Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 7A 240 V 28 V Push to Reset 1 None -
2210-T220-K0M1-H1A1-1A E-T-A 2210-T220-K0M1-H1A1-1A 162.8700
RFQ
ECAD 1801 0.00000000 E-T-A 2210-T2 Bulk Active DIN Rail CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 - ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 1A 480 V 65 V Lever 2 None -
3120-F321-P7T1-W16HT4-5A E-T-A 3120-F321-P7T1-W16HT4-5A -
RFQ
ECAD 3841 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 5A 250 V 50 V Rocker 2 None -
1410-L210-L2F1-S02-5A E-T-A 1410-L210-L2F1-S02-5A 13.7700
RFQ
ECAD 486 0.00000000 E-T-A 1410-L2 Bulk Active PCB CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 50 Thermal 5A 250 V 50 V Push to Reset 1 None -
3120-F313-P7T1-W02F-4A E-T-A 3120-F313-P7T1-W02F-4A -
RFQ
ECAD 4528 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 4A 250 V 50 V Rocker 1 None -
3120-F523-P7T1-W02D-10A E-T-A 3120-F523-P7T1-W02D-10A -
RFQ
ECAD 8571 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 10A 250 V 50 V Rocker 2 None -
8345-B01A-V3T1-DB1B2B-40A-V E-T-A 8345-B01A-V3T1-DB1B2B-40A-V 107.6390
RFQ
ECAD 3095 0.00000000 E-T-A 8345 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 40A 480 V 80 V Lever 1 None -
4230-T130-K0DE-1.2A E-T-A 4230-T130-K0DE-1.2A 34.7600
RFQ
ECAD 7274 0.00000000 E-T-A 4230-T Bulk Active DIN Rail CSA C22.2 No 235, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal Magnetic 1.2A 480 V 125 V Lever 3 None -
1658-G21-06-P13-8A E-T-A 1658-G21-06-P13-8A 4.0693
RFQ
ECAD 2939 0.00000000 E-T-A 1658 Bulk Active Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 8A 240 V 28 V Push to Reset 1 None -
157-P10-KF-25A E-T-A 157-P10-KF-25A -
RFQ
ECAD 4622 0.00000000 E-T-A 157 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 25A 250 V 50 V Push to Reset 1 None -
3120-F323-P7T1-W14XR3-15A E-T-A 3120-F323-P7T1-W14XR3-15A -
RFQ
ECAD 9737 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Thermal 15A 250 V 50 V Rocker 2 Red 90V
1658-G41-05-S80-055800-30A E-T-A 1658-G41-05-S80-055800-30A 5.0742
RFQ
ECAD 2232 0.00000000 E-T-A 1658 Bulk Active Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 30A 240 V 28 V Push to Reset 1 None -
1658-G41-04-S80-055843-25A E-T-A 1658-G41-04-S80-055843-25A 4.5410
RFQ
ECAD 4943 0.00000000 E-T-A 1658 Bulk Active Panel Mount CE, CSA C22.2 No 235, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 250 Thermal 25A 240 V 28 V Push to Reset 1 None -
8345-B23A-L6T2-DB1B2B-30A E-T-A 8345-B23A-L6T2-DB1B2B-30A 233.7950
RFQ
ECAD 2782 0.00000000 E-T-A 8345 Bulk Active Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 10 Magnetic (Hydraulic Delay) 30A 415 V 80 V Lever 3 None -
3120-F561-N7Q1-W14DR3-16A E-T-A 3120-F561-N7Q1-W14DR3-16A -
RFQ
ECAD 4886 0.00000000 E-T-A 3120-F Bulk Obsolete Panel Mount CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Thermal 16A 250 V 50 V Rocker 4 Red 115V
ESS31-TC-001-DC24V-3A E-T-A ESS31-TC-001-DC24V-3A 112.3800
RFQ
ECAD 5398 0.00000000 E-T-A ESS31-T Bulk Active DIN Rail EN60934, UL1077 download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.20.0020 1 Solid State 3A 30 V Pushbutton 1 Green, Orange, Red -
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse