Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Features | Base Product Number | Approval Agency | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Fuse Type | Class | Breaking Capacity @ Rated Voltage | Melting I²t | DC Cold Resistance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
KLNR450.X | 662.1100 | ![]() |
3458 | 0.00000000 | Littelfuse Inc. | POWR-GARD® KLNR | Box | Active | - | Electrical, Industrial | 2.594" Dia x 10.374" L (65.90mm x 263.50mm) | Requires Holder | Cylindrical, Blade Terminals | - | CE, CSA, UL | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 1 | 450A | 250 VAC | 125 VDC | Fast Blow | Cartridge | RK1 | 200kA AC, 20kA DC | |||||
![]() |
LPS-RK-250SPI | 847.2200 | ![]() |
7638 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | ||||||||||||||||||||
![]() |
170M1516 | 185.3500 | ![]() |
1931 | 0.00000000 | Eaton - Bussmann Electrical Division | 170M | Bulk | Active | - | Electrical, Industrial | - | Requires Holder | Rectangular, Blade | - | UL | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 5 | - | 700 VAC | - | Square | - | - | |||||||
C308F-V-63MA-TR1 | 4.5400 | ![]() |
2 | 0.00000000 | Eaton - Electronics Division | C308F | Tape & Reel (TR) | Active | -55°C ~ 125°C | Hazardous Locations | 0.120" Dia x 0.343" L (3.05mm x 8.70mm) | Through Hole | Cartridge, Non-Standard (Axial) | Intrinsically Safe | C308F | cURus | download | ROHS3 Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1,500 | 63mA | 250 VAC | 250 VDC | Fast Blow | Cartridge, Ceramic | - | 4kA | 0.00012 | 8.8 Ohms | ||||
![]() |
KLNR100.V | 125.6700 | ![]() |
3083 | 0.00000000 | Littelfuse Inc. | POWR-GARD® KLNR | Box | Active | - | Electrical, Industrial | 1.063" Dia x 5.874" L (27.00mm x 149.20mm) | Requires Holder | Cylindrical, Blade Terminals | - | CE, CSA, UL | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 1 | 100A | 250 VAC | 125 VDC | Fast Blow | Cartridge | RK1 | 200kA AC, 20kA DC | |||||
![]() |
64912-250 | - | ![]() |
7242 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | - | - | RoHS Compliant | Not Applicable | EAR99 | 8536.30.8000 | 1 | |||||||||||||||||
![]() |
15XABR40 | - | ![]() |
6217 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | - | 0.748" Dia x 4.921" L (19.00mm x 125.00mm) | Through Hole | Fuse Link | - | - | - | RoHS Compliant | Not Applicable | EAR99 | 8536.30.8000 | 25 | - | - | - | - | - | ||||||||
![]() |
BK/GMQ-2 | 13.2350 | ![]() |
4308 | 0.00000000 | Eaton - Electronics Division | GMQ | Bulk | Active | - | Electrical, Industrial | - | Requires Holder | Cartridge, Non-Standard | - | CE, CSA, UL | download | RoHS Compliant | 1 (Unlimited) | BK-GMQ-2 | EAR99 | 8536.10.0040 | 100 | 2A | 300 VAC | Slow Blow | Cartridge | - | 10kA | ||||||
![]() |
170M3712 | 383.0700 | ![]() |
5881 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 1.969" L x 1.772" W x 2.323" H (50.00mm x 45.00mm x 59.00mm) | Bolt Mount | Rectangular, Blade | - | CSA, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | 100A | 700 VAC | - | Square | - | 200kA | 360 | ||||||
![]() |
004110549 | 269.1200 | ![]() |
1121 | 0.00000000 | Altech Corporation | - | Bulk | Active | - | - | - | - | - | - | 0041105 | - | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8535.10.0040 | 1 | 400A | 1.1 kVDC | - | - | - | - | |||||
![]() |
FWX-1500AH | 2.0000 | ![]() |
8961 | 0.00000000 | Eaton - Bussmann Electrical Division | FWX | Bulk | Active | - | Electrical, Industrial | 3.500" Dia x 2.590" L (88.90mm x 65.79mm) | Requires Holder | Cartridge, Non-Standard | - | CE, CSA, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 1 | 1.5kA | 250 VAC | 250 VDC | - | Cartridge | - | 200kA | 120000 | |||||
![]() |
LA070URD31TTI0630 | - | ![]() |
5102 | 0.00000000 | Littelfuse Inc. | POWR-GARD® LA | Box | Obsolete | - | Electrical, Industrial | 1.992" L x 2.000" W x 2.264" H (50.60mm x 50.80mm x 57.50mm) | Bolt Mount | Rectangular | - | UR | download | RoHS non-compliant | 1 (Unlimited) | -LA070URD31TTI0630 | EAR99 | 8536.10.0040 | 1 | 630A | 700 VAC | Fast Blow | Square | - | 200kA | 75 | |||||
![]() |
EV10-40-B | - | ![]() |
5330 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | - | CE | - | Not Applicable | 2041-EV10-40-B | 1 | 40A | 500 VDC | - | Cartridge | - | 20kA | 1720 | ||||||||
![]() |
PF-HT1-25 | 27.5700 | ![]() |
50 | 0.00000000 | Bourns Inc. | POWrFuse™ PF-H | Tray | Active | -55°C ~ 125°C | Solar (Photovoltaic) | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | Through Hole | Radial Bend Cylinder | - | cULus, TUV, UL | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 118-PF-HT1-25 | EAR99 | 8536.10.0040 | 50 | 25A | 600 VAC | 600 VDC | - | Cartridge, Ceramic | - | 150kA AC, 50kA DC | 1607.18 | 3.745 mOhms | ||
![]() |
FWP-60D | 262.3740 | ![]() |
3513 | 0.00000000 | Eaton - Bussmann Electrical Division | FWP | Bulk | Active | - | Electrical, Industrial | 0.831" Dia x 1.112" L (21.10mm x 28.25mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | - | CE, CSA, UL | - | Not Applicable | 2041-FWP-60D | 5 | 60A | 700 VAC | 700 VDC | - | Cartridge | - | 200kA AC, 50kA DC | 210 | |||||||
![]() |
0FLA012.V | 23.7040 | ![]() |
2680 | 0.00000000 | Littelfuse Inc. | FLA | Bulk | Active | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | Requires Holder | 5AG, 10mm x 38mm (Midget) | Indicating | UL | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 5 | 12A | 125 V | Slow Blow | Cartridge | - | 10kA | 0.00689 Ohms | |||||
![]() |
0KLQ001.T | 12.8320 | ![]() |
9843 | 0.00000000 | Littelfuse Inc. | POWR-GARD® KLQ | Bulk | Active | -55°C ~ 125°C | Electrical, Industrial | 0.406" Dia x 1.375" L (10.31mm x 34.93mm) | Requires Holder | 5AG, 10mm x 38mm (Midget) | - | CE, UL | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 10 | 1A | 600 V | Slow Blow | Cartridge | - | 10kA | 1.414 Ohms | |||||
![]() |
200E1C5.5 | - | ![]() |
8599 | 0.00000000 | Littelfuse Inc. | POWR-GARD® | Bulk | Active | - | Transformer Protection | 3.000" Dia x 15.875" L (76.20mm x 403.23mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS non-compliant | 1 (Unlimited) | -200E1C5.5 | EAR99 | 8536.10.0040 | 1 | 200A | 5.5 kV | - | Cartridge | E | 80kA | ||||||
![]() |
C10G8I | - | ![]() |
3672 | 0.00000000 | Eaton - Bussmann Electrical Division | C10G | Bulk | Obsolete | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.30mm x 38.00mm) | Requires Holder | Cylindrical, Alarm Indicating, 5AG, 10x38.1mm | Indicating | - | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8536.10.0040 | 10 | 8A | 500 VAC | - | Cartridge | - | 120kA | |||||||
![]() |
FRS-R-25 | 48.0600 | ![]() |
8 | 0.00000000 | Eaton - Bussmann Electrical Division | Fusetron™ FRS-R | Bulk | Active | - | Electrical, Industrial | 0.810" Dia x 3.00" L (20.57mm x 76.20mm) | Requires Holder | Cartridge, Non-Standard | - | CE, CSA, UL | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 25A | 600 VAC | 300 VDC | Slow Blow | Cartridge | RK5 | 200kA AC, 20kA DC | ||||||
![]() |
T-1 | 46.2800 | ![]() |
4586 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | download | RoHS Compliant | Not Applicable | T-1EB | EAR99 | 8538.90.8180 | 4 | |||||||||||||||||||
![]() |
FWC-16A10F | 51.9100 | ![]() |
8490 | 0.00000000 | Eaton - Bussmann Electrical Division | FWC | Bulk | Active | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | Requires Holder | 5AG, 10mm x 38mm (Midget) | - | CE, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 | 16A | 600 VAC | 700 VDC | - | Cartridge | - | 50kA | 25 | |||||
![]() |
170M3697 | 735.3650 | ![]() |
7070 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Active | - | Electrical, Industrial | 2.913" L x 1.772" W x 2.323" H (74.00mm x 45.00mm x 59.00mm) | Bolt Mount | Rectangular, Blade | Indicating | CSA, UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0040 | 2 | 350A | 1.3 kVAC | - | Square | - | 100kA | 27000 | ||||||
![]() |
0JLS150.X | 146.3100 | ![]() |
5877 | 0.00000000 | Littelfuse Inc. | POWR-GARD® JLS | Bulk | Active | - | Electrical, Industrial | 1.500" Dia x 3.000" L (38.10mm x 76.20mm) | Requires Holder | Cylindrical, Blade Terminals | - | CE, CSA, QPL, UL | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 1 | 150A | 600 V | Fast Blow | Cartridge | J | 200kA | ||||||
![]() |
2009R1C8.25 | - | ![]() |
5284 | 0.00000000 | Littelfuse Inc. | POWR-GARD® | Bulk | Active | - | Motor Protection | 3.000" Dia x 15.875" L (76.20mm x 403.23mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS non-compliant | 1 (Unlimited) | -2009R1C8.25 | EAR99 | 8535.10.0020 | 1 | 200A | 8.25 kV | - | Cartridge | R | 80kA | ||||||
![]() |
ITV4030L1215NR | 4.4000 | ![]() |
4 | 0.00000000 | Littelfuse Inc. | POLYSWITCH®, ITV4030 | Tape & Reel (TR) | Active | -10°C ~ 65°C | Battery Protection | 0.157" L x 0.118" W x 0.035" H (4.00mm x 3.00mm x 0.90mm) | Surface Mount | 1612 (4030 Metric) | 7.4 ~ 13.8V Triggerable | cURus, TUV | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 5,000 | 15A | 36 VDC | Fast Blow | Board Mount | - | 50A | 0.0000085 Ohms | |||||
![]() |
50NHC00M | - | ![]() |
6882 | 0.00000000 | Eaton - Bussmann Electrical Division | - | Bulk | Obsolete | - | Electrical, Industrial | 2.126" L x 1.181" W x 1.969" H (54.00mm x 30.00mm x 50.00mm) | Requires Holder | Rectangular, Blade | Indicating | VDE | download | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 3 | 50A | 500 VAC | 250 VDC | Fast Blow | Square | NH | 120kA AC, 50kA DC | ||||||
![]() |
DCM-5 | - | ![]() |
2903 | 0.00000000 | Eaton - Bussmann Electrical Division | DCM | Bulk | Obsolete | - | Electrical, Industrial | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | Requires Holder | 5AG, 10mm x 38mm (Midget) | - | CSA, UL | download | 1 (Unlimited) | REACH Unaffected | EAR99 | 8536.10.0040 | 10 | 5A | 600 VAC | 600 VDC | Fast Blow | Cartridge | - | 100kA AC, 50kA DC | ||||||
![]() |
PSR031FL0315Z | 322.7000 | ![]() |
2487 | 0.00000000 | Littelfuse Inc. | POWR-SPEED® PSR | Box | Active | -55°C ~ 125°C | Semiconductors | 1.969" L x 2.028" W x 2.264" H (50.00mm x 51.50mm x 57.50mm) | Bolt Mount | - | Indicating | CCC, CE, cURus, UL | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8536.10.0040 | 1 | 315A | 700 VAC | 600 VDC | Fast Blow | Square | - | 200kA AC, 150kA DC | 6862 | ||||
![]() |
KTN-R-10 | 75.1200 | ![]() |
8105 | 0.00000000 | Eaton - Bussmann Electrical Division | * | Bulk | Active | - | RoHS Compliant | Not Applicable | EAR99 | 8536.10.0040 | 10 |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse