SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Features Approval Agency DataSheet RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Standard Package Current Rating (Amps) Voltage Rating - AC Response Time Fuse Type Class Breaking Capacity @ Rated Voltage
JCH-3R Eaton - Bussmann Electrical Division JCH-3R -
RFQ
ECAD 2601 0.00000000 Eaton - Bussmann Electrical Division JCH Bulk Active - Motor Protection 3.000" Dia x 10.880" L (76.20mm x 276.35mm) Requires Holder Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 100A 2.4 kVAC - Cartridge R 50kA
JCK-A-12R Eaton - Bussmann Electrical Division JCK-A-12R -
RFQ
ECAD 8550 0.00000000 Eaton - Bussmann Electrical Division JCK-A Bulk Active - Motor Protection 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) Requires Holder Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 230A 2.4 kVAC - Cartridge R 50kA
JCK-A-6R Eaton - Bussmann Electrical Division JCK-A-6R -
RFQ
ECAD 5229 0.00000000 Eaton - Bussmann Electrical Division JCK-A Bulk Active - Motor Protection 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) Requires Holder Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 170A 2.4 kVAC - Cartridge R 50kA
JCK-B-12R Eaton - Bussmann Electrical Division JCK-B-12R -
RFQ
ECAD 9769 0.00000000 Eaton - Bussmann Electrical Division JCK-B Bulk Active - Motor Protection 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) Bolt Mount Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 230A 2.4 kVAC - Cartridge R 50kA
JCK-B-24R Eaton - Bussmann Electrical Division JCK-B-24R -
RFQ
ECAD 1766 0.00000000 Eaton - Bussmann Electrical Division JCK-B Bulk Active - Motor Protection 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) Bolt Mount Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 450A 2.4 kVAC - Cartridge R 50kA
JCL-2R Eaton - Bussmann Electrical Division JCL-2R 1.0000
RFQ
ECAD 2802 0.00000000 Eaton - Bussmann Electrical Division JCL Bulk Active - Motor Protection - Requires Holder - Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 70A 4.8 kVAC - Cartridge R 50kA
JCL-B-12R Eaton - Bussmann Electrical Division JCL-B-12R -
RFQ
ECAD 8040 0.00000000 Eaton - Bussmann Electrical Division JCL-B Bulk Active - Motor Protection 17.88" Dia x 19.25" L (454.10mm x 488.90mm) Bolt Mount Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 230A 4.8 kVAC - Cartridge R 50kA
JCL-B-2R Eaton - Bussmann Electrical Division JCL-B-2R -
RFQ
ECAD 6809 0.00000000 Eaton - Bussmann Electrical Division JCL-B Bulk Active - Motor Protection 17.88" Dia x 19.25" L (454.10mm x 488.90mm) Bolt Mount Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 70A 4.8 kVAC - Cartridge R 50kA
JCL-B-3R Eaton - Bussmann Electrical Division JCL-B-3R 1.0000
RFQ
ECAD 7621 0.00000000 Eaton - Bussmann Electrical Division JCL-B Bulk Active - Motor Protection 17.88" Dia x 19.25" L (454.10mm x 488.90mm) Bolt Mount Cartridge, Non-Standard Indicating UR download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 100A 4.8 kVAC - Cartridge R 50kA
JCN-150E Eaton - Bussmann Electrical Division JCN-150E -
RFQ
ECAD 4657 0.00000000 Eaton - Bussmann Electrical Division JCN Bulk Active - Transformer Protection - Requires Holder - - - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 - 14.4 kVAC - Cartridge E -
JCN-25E Eaton - Bussmann Electrical Division JCN-25E -
RFQ
ECAD 3311 0.00000000 Eaton - Bussmann Electrical Division JCN Bulk Active - Transformer Protection - Requires Holder - - - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 - 14.4 kVAC - Cartridge E -
JCN-40E Eaton - Bussmann Electrical Division JCN-40E -
RFQ
ECAD 5967 0.00000000 Eaton - Bussmann Electrical Division JCN Bulk Active - Transformer Protection - Requires Holder - - - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 - 14.4 kVAC - Cartridge E -
JCN-80E Eaton - Bussmann Electrical Division JCN-80E -
RFQ
ECAD 9359 0.00000000 Eaton - Bussmann Electrical Division JCN Bulk Active - Transformer Protection - Requires Holder - - - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 - 14.4 kVAC - Cartridge E -
JCR-A-12R Eaton - Bussmann Electrical Division JCR-A-12R -
RFQ
ECAD 3873 0.00000000 Eaton - Bussmann Electrical Division JCR-A Bulk Obsolete - Motor Protection 3.000" Dia x 15.850" L (76.20mm x 402.60mm) Requires Holder Cartridge, Non-Standard Indicating UR download RoHS Compliant 1 (Unlimited) EAR99 8535.10.0020 1 230A 7.2 kVAC - Cartridge R 50kA
JCR-B-18R Eaton - Bussmann Electrical Division JCR-B-18R -
RFQ
ECAD 1252 0.00000000 Eaton - Bussmann Electrical Division JCR-B Bulk Obsolete - Motor Protection 17.88" Dia x 19.25" L (454.10mm x 488.90mm) Bolt Mount Cylindrical, Blade Terminal (Bolt) Indicating UR download RoHS Compliant 1 (Unlimited) EAR99 8535.10.0020 1 390A 7.2 kVAC - Cartridge R 50kA
JCR-B-24R Eaton - Bussmann Electrical Division JCR-B-24R -
RFQ
ECAD 4696 0.00000000 Eaton - Bussmann Electrical Division JCR-B Bulk Obsolete - Motor Protection 17.88" Dia x 19.25" L (454.10mm x 488.90mm) Bolt Mount Cylindrical, Blade Terminal (Bolt) Indicating UR download RoHS Compliant 1 (Unlimited) EAR99 8535.10.0020 1 450A 7.2 kVAC - Cartridge R 50kA
JCR-B-9R Eaton - Bussmann Electrical Division JCR-B-9R -
RFQ
ECAD 4933 0.00000000 Eaton - Bussmann Electrical Division JCR-B Bulk Obsolete - Motor Protection 17.88" Dia x 19.25" L (454.10mm x 488.90mm) Bolt Mount Cylindrical, Blade Terminal (Bolt) Indicating UR download RoHS Compliant 1 (Unlimited) EAR99 8535.10.0020 1 200A 7.2 kVAC - Cartridge R 50kA
JCU-400E Eaton - Bussmann Electrical Division JCU-400E -
RFQ
ECAD 3830 0.00000000 Eaton - Bussmann Electrical Division JCU Bulk Active - Transformer Protection 3.000" Dia x 17.875" L (76.20mm x 454.03mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 400A 5.5 kVAC - Cartridge E 63kA
JCU-40E Eaton - Bussmann Electrical Division JCU-40E -
RFQ
ECAD 2819 0.00000000 Eaton - Bussmann Electrical Division JCU Bulk Active - Transformer Protection 3.000" Dia x 17.875" L (76.20mm x 454.03mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 40A 5.5 kVAC - Cartridge E 63kA
JCU-450E Eaton - Bussmann Electrical Division JCU-450E -
RFQ
ECAD 9407 0.00000000 Eaton - Bussmann Electrical Division JCU Bulk Active - Transformer Protection 3.000" Dia x 17.875" L (76.20mm x 454.03mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 450A 5.5 kVAC - Cartridge E 63kA
JCW-2E Eaton - Bussmann Electrical Division JCW-2E 692.1300
RFQ
ECAD 8853 0.00000000 Eaton - Bussmann Electrical Division JCW Bulk Active - Transformer Protection 1.563" Dia x 7.312" L (39.70mm x 185.72mm) Requires Holder Cartridge, Non-Standard - - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 2A 5.5 kVAC - Cartridge E 40kA
JCW-3E Eaton - Bussmann Electrical Division JCW-3E 692.4900
RFQ
ECAD 5393 0.00000000 Eaton - Bussmann Electrical Division JCW Bulk Active - Transformer Protection 1.563" Dia x 7.312" L (39.70mm x 185.72mm) Requires Holder Cartridge, Non-Standard - - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 3A 5.5 kVAC - Cartridge E 40kA
JCX-100E Eaton - Bussmann Electrical Division JCX-100E 2.0000
RFQ
ECAD 8159 0.00000000 Eaton - Bussmann Electrical Division JCX Bulk Active - Transformer Protection 3.000" Dia x 10.880" L (76.20mm x 276.35mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 100A 2.4 kVAC - Cartridge E 40kA
JCX-1E Eaton - Bussmann Electrical Division JCX-1E 1.0000
RFQ
ECAD 6469 0.00000000 Eaton - Bussmann Electrical Division JCX Bulk Active - Transformer Protection 2.000" Dia x 9.190" L (50.80mm x 233.38mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 1A 2.4 kVAC - Cartridge E 40kA
JCX-40E Eaton - Bussmann Electrical Division JCX-40E 2.0000
RFQ
ECAD 4728 0.00000000 Eaton - Bussmann Electrical Division JCX Bulk Active - Transformer Protection 3.000" Dia x 10.880" L (76.20mm x 276.35mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 40A 2.4 kVAC - Cartridge E 50kA
JCX-50E Eaton - Bussmann Electrical Division JCX-50E 1.0000
RFQ
ECAD 5290 0.00000000 Eaton - Bussmann Electrical Division JCX Bulk Active - Transformer Protection 3.000" Dia x 10.880" L (76.20mm x 276.35mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 50A 2.4 kVAC - Cartridge E 50kA
JCX-80E Eaton - Bussmann Electrical Division JCX-80E 2.0000
RFQ
ECAD 1689 0.00000000 Eaton - Bussmann Electrical Division JCX Bulk Active - Transformer Protection 3.000" Dia x 10.880" L (76.20mm x 276.35mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 80A 2.4 kVAC - Cartridge E 50kA
JCY-10E Eaton - Bussmann Electrical Division JCY-10E 1.0000
RFQ
ECAD 9511 0.00000000 Eaton - Bussmann Electrical Division JCY Bulk Active - Transformer Protection 2.000" Dia x 11.190" L (50.80mm x 284.18mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 10A 5.5 kVAC - Cartridge E 40kA
JCY-300E Eaton - Bussmann Electrical Division JCY-300E 4.0000
RFQ
ECAD 2010 0.00000000 Eaton - Bussmann Electrical Division JCY Bulk Active - Transformer Protection 2.000" Dia x 11.190" L (50.80mm x 284.18mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 300A 5.5 kVAC - Cartridge E 40kA
JCY-40E Eaton - Bussmann Electrical Division JCY-40E 1.0000
RFQ
ECAD 2744 0.00000000 Eaton - Bussmann Electrical Division JCY Bulk Active - Transformer Protection 2.000" Dia x 11.190" L (50.80mm x 284.18mm) Requires Holder Cartridge, Non-Standard Indicating - download RoHS Compliant Not Applicable EAR99 8535.10.0020 1 40A 5.5 kVAC - Cartridge E 40kA
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2