Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Package / Case | Features | Approval Agency | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | ECCN | HTSUS | Standard Package | Current Rating (Amps) | Voltage Rating - AC | Response Time | Fuse Type | Class | Breaking Capacity @ Rated Voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
JCH-3R | - | 2601 | 0.00000000 | Eaton - Bussmann Electrical Division | JCH | Bulk | Active | - | Motor Protection | 3.000" Dia x 10.880" L (76.20mm x 276.35mm) | Requires Holder | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 100A | 2.4 kVAC | - | Cartridge | R | 50kA | |||
JCK-A-12R | - | 8550 | 0.00000000 | Eaton - Bussmann Electrical Division | JCK-A | Bulk | Active | - | Motor Protection | 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) | Requires Holder | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 230A | 2.4 kVAC | - | Cartridge | R | 50kA | |||
JCK-A-6R | - | 5229 | 0.00000000 | Eaton - Bussmann Electrical Division | JCK-A | Bulk | Active | - | Motor Protection | 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) | Requires Holder | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 170A | 2.4 kVAC | - | Cartridge | R | 50kA | |||
JCK-B-12R | - | 9769 | 0.00000000 | Eaton - Bussmann Electrical Division | JCK-B | Bulk | Active | - | Motor Protection | 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) | Bolt Mount | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 230A | 2.4 kVAC | - | Cartridge | R | 50kA | |||
JCK-B-24R | - | 1766 | 0.00000000 | Eaton - Bussmann Electrical Division | JCK-B | Bulk | Active | - | Motor Protection | 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) | Bolt Mount | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 450A | 2.4 kVAC | - | Cartridge | R | 50kA | |||
JCL-2R | 1.0000 | 2802 | 0.00000000 | Eaton - Bussmann Electrical Division | JCL | Bulk | Active | - | Motor Protection | - | Requires Holder | - | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 70A | 4.8 kVAC | - | Cartridge | R | 50kA | |||
JCL-B-12R | - | 8040 | 0.00000000 | Eaton - Bussmann Electrical Division | JCL-B | Bulk | Active | - | Motor Protection | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) | Bolt Mount | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 230A | 4.8 kVAC | - | Cartridge | R | 50kA | |||
JCL-B-2R | - | 6809 | 0.00000000 | Eaton - Bussmann Electrical Division | JCL-B | Bulk | Active | - | Motor Protection | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) | Bolt Mount | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 70A | 4.8 kVAC | - | Cartridge | R | 50kA | |||
JCL-B-3R | 1.0000 | 7621 | 0.00000000 | Eaton - Bussmann Electrical Division | JCL-B | Bulk | Active | - | Motor Protection | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) | Bolt Mount | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 100A | 4.8 kVAC | - | Cartridge | R | 50kA | |||
JCN-150E | - | 4657 | 0.00000000 | Eaton - Bussmann Electrical Division | JCN | Bulk | Active | - | Transformer Protection | - | Requires Holder | - | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | - | 14.4 kVAC | - | Cartridge | E | - | |||
JCN-25E | - | 3311 | 0.00000000 | Eaton - Bussmann Electrical Division | JCN | Bulk | Active | - | Transformer Protection | - | Requires Holder | - | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | - | 14.4 kVAC | - | Cartridge | E | - | |||
JCN-40E | - | 5967 | 0.00000000 | Eaton - Bussmann Electrical Division | JCN | Bulk | Active | - | Transformer Protection | - | Requires Holder | - | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | - | 14.4 kVAC | - | Cartridge | E | - | |||
JCN-80E | - | 9359 | 0.00000000 | Eaton - Bussmann Electrical Division | JCN | Bulk | Active | - | Transformer Protection | - | Requires Holder | - | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | - | 14.4 kVAC | - | Cartridge | E | - | |||
JCR-A-12R | - | 3873 | 0.00000000 | Eaton - Bussmann Electrical Division | JCR-A | Bulk | Obsolete | - | Motor Protection | 3.000" Dia x 15.850" L (76.20mm x 402.60mm) | Requires Holder | Cartridge, Non-Standard | Indicating | UR | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8535.10.0020 | 1 | 230A | 7.2 kVAC | - | Cartridge | R | 50kA | |||
JCR-B-18R | - | 1252 | 0.00000000 | Eaton - Bussmann Electrical Division | JCR-B | Bulk | Obsolete | - | Motor Protection | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | Indicating | UR | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8535.10.0020 | 1 | 390A | 7.2 kVAC | - | Cartridge | R | 50kA | |||
JCR-B-24R | - | 4696 | 0.00000000 | Eaton - Bussmann Electrical Division | JCR-B | Bulk | Obsolete | - | Motor Protection | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | Indicating | UR | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8535.10.0020 | 1 | 450A | 7.2 kVAC | - | Cartridge | R | 50kA | |||
JCR-B-9R | - | 4933 | 0.00000000 | Eaton - Bussmann Electrical Division | JCR-B | Bulk | Obsolete | - | Motor Protection | 17.88" Dia x 19.25" L (454.10mm x 488.90mm) | Bolt Mount | Cylindrical, Blade Terminal (Bolt) | Indicating | UR | download | RoHS Compliant | 1 (Unlimited) | EAR99 | 8535.10.0020 | 1 | 200A | 7.2 kVAC | - | Cartridge | R | 50kA | |||
JCU-400E | - | 3830 | 0.00000000 | Eaton - Bussmann Electrical Division | JCU | Bulk | Active | - | Transformer Protection | 3.000" Dia x 17.875" L (76.20mm x 454.03mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 400A | 5.5 kVAC | - | Cartridge | E | 63kA | |||
JCU-40E | - | 2819 | 0.00000000 | Eaton - Bussmann Electrical Division | JCU | Bulk | Active | - | Transformer Protection | 3.000" Dia x 17.875" L (76.20mm x 454.03mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 40A | 5.5 kVAC | - | Cartridge | E | 63kA | |||
JCU-450E | - | 9407 | 0.00000000 | Eaton - Bussmann Electrical Division | JCU | Bulk | Active | - | Transformer Protection | 3.000" Dia x 17.875" L (76.20mm x 454.03mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 450A | 5.5 kVAC | - | Cartridge | E | 63kA | |||
JCW-2E | 692.1300 | 8853 | 0.00000000 | Eaton - Bussmann Electrical Division | JCW | Bulk | Active | - | Transformer Protection | 1.563" Dia x 7.312" L (39.70mm x 185.72mm) | Requires Holder | Cartridge, Non-Standard | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 2A | 5.5 kVAC | - | Cartridge | E | 40kA | |||
JCW-3E | 692.4900 | 5393 | 0.00000000 | Eaton - Bussmann Electrical Division | JCW | Bulk | Active | - | Transformer Protection | 1.563" Dia x 7.312" L (39.70mm x 185.72mm) | Requires Holder | Cartridge, Non-Standard | - | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 3A | 5.5 kVAC | - | Cartridge | E | 40kA | |||
JCX-100E | 2.0000 | 8159 | 0.00000000 | Eaton - Bussmann Electrical Division | JCX | Bulk | Active | - | Transformer Protection | 3.000" Dia x 10.880" L (76.20mm x 276.35mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 100A | 2.4 kVAC | - | Cartridge | E | 40kA | |||
JCX-1E | 1.0000 | 6469 | 0.00000000 | Eaton - Bussmann Electrical Division | JCX | Bulk | Active | - | Transformer Protection | 2.000" Dia x 9.190" L (50.80mm x 233.38mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 1A | 2.4 kVAC | - | Cartridge | E | 40kA | |||
JCX-40E | 2.0000 | 4728 | 0.00000000 | Eaton - Bussmann Electrical Division | JCX | Bulk | Active | - | Transformer Protection | 3.000" Dia x 10.880" L (76.20mm x 276.35mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 40A | 2.4 kVAC | - | Cartridge | E | 50kA | |||
JCX-50E | 1.0000 | 5290 | 0.00000000 | Eaton - Bussmann Electrical Division | JCX | Bulk | Active | - | Transformer Protection | 3.000" Dia x 10.880" L (76.20mm x 276.35mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 50A | 2.4 kVAC | - | Cartridge | E | 50kA | |||
JCX-80E | 2.0000 | 1689 | 0.00000000 | Eaton - Bussmann Electrical Division | JCX | Bulk | Active | - | Transformer Protection | 3.000" Dia x 10.880" L (76.20mm x 276.35mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 80A | 2.4 kVAC | - | Cartridge | E | 50kA | |||
JCY-10E | 1.0000 | 9511 | 0.00000000 | Eaton - Bussmann Electrical Division | JCY | Bulk | Active | - | Transformer Protection | 2.000" Dia x 11.190" L (50.80mm x 284.18mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 10A | 5.5 kVAC | - | Cartridge | E | 40kA | |||
JCY-300E | 4.0000 | 2010 | 0.00000000 | Eaton - Bussmann Electrical Division | JCY | Bulk | Active | - | Transformer Protection | 2.000" Dia x 11.190" L (50.80mm x 284.18mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 300A | 5.5 kVAC | - | Cartridge | E | 40kA | |||
JCY-40E | 1.0000 | 2744 | 0.00000000 | Eaton - Bussmann Electrical Division | JCY | Bulk | Active | - | Transformer Protection | 2.000" Dia x 11.190" L (50.80mm x 284.18mm) | Requires Holder | Cartridge, Non-Standard | Indicating | - | download | RoHS Compliant | Not Applicable | EAR99 | 8535.10.0020 | 1 | 40A | 5.5 kVAC | - | Cartridge | E | 40kA |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse