Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Ratings | Usage | Features | Base Product Number | Length | Number of Conductors | DataSheet | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Cable Type | Shield Material | Voltage | Wire Gauge | Conductor Strand | Conductor Material | Jacket (Insulation) Material | Jacket (Insulation) Diameter | Shield Type | Jacket Color | Jacket (Insulation) Thickness | Conductor Insulation | Shield Coverage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1362A 0031000 | 11.0000 | 2636 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Drain Wire, Oil Resistant, Rip Cord | 1362A | 1000.0' (304.8m) | 10 (5 Pair) | download | Not Applicable | REACH Unaffected | BEL2736-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.753" (19.13mm) | Foil | Orange | 0.0650" (1.651mm) | Polyolefin (PO) | 100% | |||
1363A 0031000 | 16.0000 | 2661 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Drain Wire, Oil Resistant | 1363A | 1000.0' (304.8m) | 16 (8 Pair) | - | Not Applicable | REACH Unaffected | BEL2737-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.914" (23.22mm) | Foil | Orange | 0.0750" (1.905mm) | Polyolefin (PO) | 100% | |||
1366A 0031000 | 30.5925 | 9490 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Drain Wire, Rip Cord | 1366A | 1000.0' (304.8m) | 40 (20 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2740-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.393" (35.38mm) | Foil | Orange | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
1498A 0101000 | 23.5174 | 4831 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 105°C | UL Style 2464 | Instrumentation | Drain Wire, Rip Cord | 1498A | 1000.0' (304.8m) | 49 (24.5 Pair) | download | Not Applicable | REACH Unaffected | BEL2741-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 300 V | 16 AWG, 22 AWG | 7/24; 7/30 | Copper, Bare | Poly-Vinyl Chloride (PVC) | 1.157" (29.39mm) | Foil | Black | 0.0740" (1.880mm) | Poly-Vinyl Chloride (PVC) | 100% | |||
2100A 0031000 | 2.0000 | 1805 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Flame Retardant, Oil Resistant, Rip Cord, UV Resistant | 2100A | 1000.0' (304.8m) | 2 (1 Pair) | - | Not Applicable | REACH Unaffected | BEL2742-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.319" (8.10mm) | Foil | Orange | - | Polyolefin (PO) | 100% | |||
2102A 0031000 | 11.0000 | 2853 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2102A | 1000.0' (304.8m) | 10 (5 Pair) | - | Not Applicable | REACH Unaffected | BEL2745-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.677" (17.20mm) | Foil | Orange | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2104A 0061000 | 24.0000 | 8916 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2104A | 1000.0' (304.8m) | 24 (12 Pair) | - | Not Applicable | REACH Unaffected | BEL2750-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.015" (25.78mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2107A 0031000 | 44.0000 | 4982 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire | 2107A | 1000.0' (304.8m) | 48 (24 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2755-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.389" (35.28mm) | Foil | Orange | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2107A 0061000 | 44.0000 | 6874 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire | 2107A | 1000.0' (304.8m) | 48 (24 Pair Twisted) | - | Not Applicable | REACH Unaffected | BEL2756-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.389" (35.28mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2108A 0031000 | 74.3310 | 2980 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2108A | 1000.0' (304.8m) | 100 (50 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2757-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.947" (49.45mm) | Foil | Orange | 0.1200" (3.048mm) | Polyolefin (PO) | 100% | |||
2109A 0061000 | 3.0000 | 7261 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2109A | 1000.0' (304.8m) | 2 (1 Pair) | download | Not Applicable | REACH Unaffected | BEL2759-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.365" (9.27mm) | Foil | Blue | - | Polyolefin (PO) | 100% | |||
2110A 0061000 | 8.0000 | 8206 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2110A | 1000.0' (304.8m) | 4 (2 Pair) | download | Not Applicable | REACH Unaffected | BEL2761-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.629" (15.98mm) | Foil | Blue | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2111A 0031000 | 15.0000 | 5321 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2111A | 1000.0' (304.8m) | 10 (5 Pair) | download | Not Applicable | REACH Unaffected | BEL2762-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.789" (20.04mm) | Foil | Orange | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2111A 0061000 | 15.0000 | 6577 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2111A | 1000.0' (304.8m) | 10 (5 Pair) | - | Not Applicable | REACH Unaffected | BEL2763-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.789" (20.04mm) | Foil | Blue | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2112A 0061000 | 23.0000 | 8502 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2112A | 1000.0' (304.8m) | 16 (8 Pair) | - | Not Applicable | REACH Unaffected | BEL2765-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.982" (24.94mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2113A 0031000 | 33.0000 | 1477 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire, Rip Cord | 2113A | 1000.0' (304.8m) | 24 (12 Pair) | download | Not Applicable | REACH Unaffected | BEL2766-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.186" (30.12mm) | Foil | Orange | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2115A 0061000 | 48.0000 | 7623 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire | 2115A | 1000.0' (304.8m) | 40 (20 Pair Twisted) | - | Not Applicable | REACH Unaffected | BEL2771-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.469" (37.31mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2117A 0061000 | 88.0000 | 7186 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | - | - | Drain Wire | 2117A | 1000.0' (304.8m) | 72 (36 Pair Twisted) | - | Not Applicable | REACH Unaffected | BEL2775-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 300 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.952" (49.58mm) | Foil | Blue | 0.1200" (3.048mm) | Polyolefin (PO) | 100% | |||
2121A 0031000 | 16.0000 | 8962 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2121A | 1000.0' (304.8m) | 16 (8 Pair) | download | Not Applicable | REACH Unaffected | BEL2781-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 600 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.800" (20.32mm) | Foil | Orange | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2124A 0031000 | 38.0000 | 1774 | 0.00000000 | Belden Inc. | - | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Direct Burial, Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2124A | 1000.0' (304.8m) | 40 (20 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2787-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 600 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.249" (31.73mm) | Foil | Orange | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2128A 0031000 | 8.0000 | 7632 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2128A | 1000.0' (304.8m) | 4 (2 Pair) | - | Not Applicable | REACH Unaffected | BEL2794-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 600 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.629" (15.98mm) | Foil | Orange | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2129A 0061000 | 15.0000 | 9173 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2129A | 1000.0' (304.8m) | 10 (5 Pair) | download | Not Applicable | REACH Unaffected | BEL2797-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 600 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.789" (20.04mm) | Foil | Blue | 0.0630" (1.600mm) | Polyolefin (PO) | 100% | |||
2130A 0031000 | 36.0000 | 6713 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Direct Burial, Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2130A | 1000.0' (304.8m) | 16 (8 Pair) | download | Not Applicable | REACH Unaffected | BEL2798-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 600 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.982" (24.94mm) | Foil | Orange | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2130A 0061000 | 36.0000 | 2046 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Direct Burial, Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2130A | 1000.0' (304.8m) | 16 (8 Pair) | download | Not Applicable | REACH Unaffected | BEL2799-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Pair | Aluminum | 600 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.982" (24.94mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2132A 0061000 | 35.2348 | 5765 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2132A | 1000.0' (304.8m) | 32 (16 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2803-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 600 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.321" (33.55mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
2133A 0061000 | 43.1600 | 3986 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 90°C | UL Style TC-ER | - | Drain Wire, Oil Resistant, Rip Cord, UV Resistant | 2133A | 1000.0' (304.8m) | 40 (20 Pair Twisted) | download | Not Applicable | REACH Unaffected | BEL2805-1000 | EAR99 | 8544.49.3080 | 1,000 | Multi-Pair | Aluminum | 600 V | 16 AWG | 7/24 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 1.469" (37.31mm) | Foil | Blue | 0.0850" (2.159mm) | Polyolefin (PO) | 100% | |||
3072F C551000 | 5.0000 | 7490 | 0.00000000 | Belden Inc. | DataTray® | Spool | Active | -40°C ~ 75°C | - | - | Drain Wire | 3072F | 1000.0' (304.8m) | 2 (1 Pair Twisted) | - | Not Applicable | REACH Affected | BEL2810-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum; Copper, Tinned | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.324" (8.23mm) | Foil, Braid | Blue | 0.0530" (1.346mm) | Polyolefin (PO) | 100%, 55% | ||||
3076F 0061000 | 2.0000 | 1 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -40°C ~ 105°C | - | - | Direct Burial, Drain Wire, Oil Resistant, UV Resistant | 3076F | 1000.0' (304.8m) | 2 (1 Pair) | - | Not Applicable | REACH Unaffected | BEL2814-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 300 V | 18 AWG | 7/26 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.280" (7.11mm) | Foil | Blue | - | Polyolefin (PO) | 100% | |||
3077F 0031000 | 1.0000 | 9398 | 0.00000000 | Belden Inc. | DataBus® | Spool | Active | -30°C ~ 105°C | - | - | Drain Wire | 3077F | 1000.0' (304.8m) | 2 (1 Pair) | - | Not Applicable | REACH Unaffected | BEL2815-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum | 300 V | 22 AWG | 7/30 | Copper, Tinned | Poly-Vinyl Chloride (PVC) | 0.196" (4.98mm) | Foil | Orange | 0.0370" (0.940mm) | Polyolefin (PO) | 100% | |||
3079A 0601000 | 3.0000 | 7183 | 0.00000000 | Belden Inc. | - | Spool | Active | -30°C ~ 75°C | UL Style 20201 | - | Flame Retardant, UV Resistant | 3079A | 1000.0' (304.8m) | 2 (1 Pair) | - | Not Applicable | REACH Affected | BEL2818-1000 | EAR99 | 8544.49.3080 | 1 | Multi-Conductor | Aluminum; Copper, Tinned | 22 AWG | Solid | Copper, Bare | Poly-Vinyl Chloride (PVC) | 0.315" (8.00mm) | Foil, Braid | Chrome | - | Foam Polyethylene (FPE) | 100%, 65% |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse